I2C/SPI Triggering and Serial Decode
24
Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide
363
3
In the Trigger Menu, press the
Trigger
softkey; then, turn the Entry knob
to select the serial slot (Serial 1 or Serial 2) on which the I
2
C signals
are being decoded.
4
Press the
Trigger:
softkey; then, turn the Entry knob to select the trigger
condition:
•
Start Condition
— The oscilloscope triggers when SDA data transitions
from high to low while the SCL clock is high. For triggering purposes
(including frame triggers), a restart is treated as a start condition.
•
Stop Condition
— The oscilloscope triggers when data (SDA) transitions
from low to high while the clock (SCL) is high.
•
Missing Acknowledge
— The oscilloscope triggers when SDA data is high
during any Ack SCL clock bit.
•
Address with no Ack
— The oscilloscope triggers when the acknowledge
of the selected address field is false. The R/W bit is ignored.
•
Restart
— The oscilloscope triggers when another start condition occurs
before a stop condition.
•
EEPROM Data Read
— The trigger looks for EEPROM control byte value
1010xxx on the SDA line, followed by a Read bit and an Ack bit. It
then looks for the data value and qualifier set by the
Data
softkey
and the
Data is
softkey. When this event occurs, the oscilloscope will
trigger on the clock edge for the Ack bit after the data byte. This
data byte does not need to occur directly after the control byte.
SDA
SCL
Stop
Condition
R/
Start
Condition
Ack
Ack
Data
Address
Содержание InfiniiVision 3000 3024A MSO-X
Страница 1: ...s1 Agilent InfiniiVision 3000 X Series Oscilloscopes User s Guide ...
Страница 22: ...22 Agilent InfiniiVision 3000 X Series Oscilloscopes User s Guide ...
Страница 122: ...122 Agilent InfiniiVision 3000 X Series Oscilloscopes User s Guide 6 Digital Channels ...
Страница 128: ...128 Agilent InfiniiVision 3000 X Series Oscilloscopes User s Guide 7 Serial Decode ...
Страница 134: ...134 Agilent InfiniiVision 3000 X Series Oscilloscopes User s Guide 8 Display Settings ...
Страница 140: ...140 Agilent InfiniiVision 3000 X Series Oscilloscopes User s Guide 9 Labels ...
Страница 176: ...176 Agilent InfiniiVision 3000 X Series Oscilloscopes User s Guide 10 Triggers ...
Страница 184: ...184 Agilent InfiniiVision 3000 X Series Oscilloscopes User s Guide 11 Trigger Mode Coupling ...
Страница 202: ...202 Agilent InfiniiVision 3000 X Series Oscilloscopes User s Guide 12 Acquisition Control ...
Страница 212: ...212 Agilent InfiniiVision 3000 X Series Oscilloscopes User s Guide 13 Cursors ...
Страница 262: ...262 Agilent InfiniiVision 3000 X Series Oscilloscopes User s Guide 16 Waveform Generator ...
Страница 278: ...278 Agilent InfiniiVision 3000 X Series Oscilloscopes User s Guide 17 Save Recall Setups Screens Data ...
Страница 300: ...300 Agilent InfiniiVision 3000 X Series Oscilloscopes User s Guide 19 Utility Settings ...
Страница 360: ...360 Agilent InfiniiVision 3000 X Series Oscilloscopes User s Guide 23 FlexRay Triggering and Serial Decode ...
Страница 380: ...380 Agilent InfiniiVision 3000 X Series Oscilloscopes User s Guide 24 I2C SPI Triggering and Serial Decode ...