N9927-90003
2-7
FieldFox Analyzer
General Product Information
Analyzer Options
Option 302, External USB Power Sensor Support
Option 302 allows the use of an external USB controllable power sensor.
All Agilent U2000x Series USB power sensors are supported with FieldFox.
Visit: www.agilent.com/find/u2000 for an up-to-date listing.
Option 305, Cable and Antenna Analyzer
Option 305 provides fast and accurate diagnosis of cables, connectors, and antennas with DTF (dB,
linear, VSWR), return loss and DTF, 1-port cable loss, 2-port insertion loss, and CalReady.
Option 307, GPS Receiver
Option 307 enables the built-in GPS receiver. Requires a GPS antenna such as N9910X-825.
Option 308, Vector Voltmeter (VVM)
Option 308 includes S11 or one-port cable trimming.
Option 309, DC Bias Variable-Voltage Source
Option 309 adds an integrated built-in variable voltage DC bias source to the FieldFox analyzer. The
source provides 1 to 32 VDC with maximum current of 650 mA and 7 watts maximum power. The DC
bias source can provide DC power to amplifiers under test and bias tower mounted amplifiers (TMA)
when engineers need to sweep through the TMA to reach the antenna. The bias-tee is available
separately. The DC output has an SMB (m) connector.
Option 310, Built-In Power Meter
Option 310 provides the functionality to make user-definable channel power measurements such as
transmitter output power. By leveraging InstAlign technology, FieldFox is able to make very accurate
channel power measurements.
Option 320, Reflection Measurements (Return Loss, VSWR, and Scalar Measurement)
Measurement of VSWR and return loss can be made on active and passive devices, cables, connectors
and antennas. Option 220 is prerequisite.
Содержание FieldFox MW N9913A
Страница 8: ...Contents 4 Service Guide N9927 90003 Contents ...
Страница 9: ...N9927 90003 1 1 1 Safety and Regulatory Information ...
Страница 16: ...1 8 N9927 90003 Safety and Regulatory Information FieldFox Analyzer Regulatory Information ...
Страница 17: ...N9927 90003 2 1 2 General Product Information ...
Страница 26: ...2 10 N9927 90003 General Product Information FieldFox Analyzer Agilent Support Services and Assistance ...
Страница 27: ...N9927 90003 3 1 3 Tests and Adjustments ...
Страница 37: ...N9927 90003 4 1 4 Troubleshooting ...
Страница 50: ...4 14 N9927 90003 Troubleshooting FieldFox Analyzer Measurement Group Troubleshooting ...
Страница 51: ...N9927 90003 5 1 5 Theory of Operation ...
Страница 58: ...5 8 N9927 90003 Theory of Operation FieldFox Analyzer Measurement Group Figure 5 2 Simplified RF Block Diagram ...
Страница 81: ...N9927 90003 6 1 6 Replaceable Parts ...
Страница 95: ...N9927 90003 7 1 7 Repair and Replacement Procedures ...
Страница 140: ...7 46 N9927 90003 Repair and Replacement Procedures FieldFox Analyzer Post Repair Procedures ...
Страница 141: ...N9927 90003 8 1 8 General Purpose Maintenance and Service Procedures ...
Страница 149: ...N9927 90003 Appendix 1 Appendix A ...
Страница 156: ...Index 4 N9927 90003 Index ...