84
Chapter 4
Analog Modulation
Configuring the LF Output
To Configure the LF Output with an Internal Modulation Source
In this example, the internal FM modulation is the LF output source.
NOTE
Internal modulation (
Internal Monitor
) is the default LF output source.
Configuring the Internal Modulation as the LF Output Source
1. Press
Preset
.
2. Press the
FM/
Φ
M
hardkey.
3. Press
FM Dev
>
75
>
kHz
.
4. Press
FM Rate
>
10
>
kHz
.
5. Press
FM Off On
.
You have set up the FM signal with a rate of 10 kHz and 75 kHz of deviation. The
FM
annunciator is
activated indicating that you have enabled frequency modulation.
Configuring the Low Frequency Output
1. Press the
LF Out
hardkey.
2. Press
LF Out Amplitude
>
3
>
Vp
.
3. Press
LF Out Off On
.
You have configured the LF output signal for a 3 volt sine wave (default wave form) output which is
frequency modulated using the
Internal 1 Monitor
source selection (default source).
Содержание E8247C
Страница 10: ...Contents x ...
Страница 96: ...86 Chapter 4 Analog Modulation Configuring the LF Output ...
Страница 127: ...Chapter 5 117 Dual Arbitrary Waveform Generator Using Waveform Clipping Figure 5 16 Rectangular Clipping ...
Страница 128: ...118 Chapter 5 Dual Arbitrary Waveform Generator Using Waveform Clipping Figure 5 17 Reduction of Peak to Average Power ...
Страница 142: ...132 Chapter 6 Custom Arb Waveform Generator Working with Filters ...
Страница 178: ...168 Chapter 7 Custom Real Time I Q Baseband Working with Differential Data Encoding ...
Страница 198: ...188 Chapter 10 Troubleshooting ...
Страница 214: ...204 Chapter 10 Troubleshooting Returning a Signal Generator to Agilent Technologies ...