108
P1512115 R8
4.26. Gas Drive — Control Box
Æ
1.
For models that do not have a welded mount bracket:
Attach the control box to the tube with 10" x 2-1/2"
u-clamp (9), 7/16" x 1-1/2" bolts (10) and 7/16" nylock nuts (11).
2. Remove the top cover (1) (see
). Tighten the u-clamp until the tube begins to crimp.
3. Mount the throttle cable (2), choke cable (5), clutch switch (3) (if equipped with an electric clutch), and
ignition switch (4).
4. Consult the OEM (original equipment manufacturers) manual to make all required electrical connections.
Remove the key, plug in the extension wiring harness (12), and fasten it to the side plastic guard on the
engine using small self-tapping screws (see
). After the conveyor is completely assembled, place
finishing zip-ties on all cables and wiring to ensure all lines are snug in place.
5. Replace the top cover and secure with 1/4" x 3/4" bolts (8), 1/4" washers (6), and 1/4" lock washers (7).
Table 47.
Control Box Components
Item
Description
Quantity
1
Control Box Top Cover
1
2
Throttle Cable
1
3
Clutch Switch
1
4
Ignition Switch
1
5
Choke Cable
1
6
1/4" Flat Washer
2
7
1/4" Lock Washer
2
8
1/4" x 3/4" Hex Bolt
2
9
10" x 2-1/2" U-clamp (Not Shown)
2
10
7/16" x 1-1/2" Bolt (Not Shown)
2
11
7/16" Nylon Locknut (Not Shown)
2
12
Extension Wiring Harness
1
PORTABLE GRAIN BELT CONVEYOR – FIELD LOADER