70
P1512115 R8
Figure 48.
Motor Mount
4.24.2 Install the Gearbox
1. Check the oil level in the gearbox. It should be 1/2 full.
2. Attach the gearbox (1) to the motor mount using 1/2" x 1-1/4" bolts (2) and 1/2" lock washers (3) (see
).
Note
Do not tighten the gearbox bolts.
3. Connect the gearbox breather (fitting, hose, vent) (4) to the gearbox breather hole (see
).
Table 28.
Gearbox Components
Item
Description
1
Gearbox 90 1:1 CW/CW 1–1/2 4190 w/Oil (For Electric Drive)
Gearbox 4190 2:1 1–1/2 Shaft (For Gas Drive)
2
1/2" x 1-1/4" Bolt Gr5 Plated
3
1/2" Lock Washer Plated
4
Breather Direct Drive
1
3
2
1
3
2
To hopper
PORTABLE GRAIN BELT CONVEYOR – FIELD LOADER