![AGI Batco 1500 SA Series Скачать руководство пользователя страница 41](http://html1.mh-extra.com/html/agi/batco-1500-sa-series/batco-1500-sa-series_operators-manual_2866988041.webp)
8210–00011 R1
41
1. Connect the positive wire directly to the positive terminal on the tractor battery and the negative wire to
the tractor chassis (see
). The negative terminal on the tractor battery should also be grounded to
the chassis. There are 5/16" lugged terminals supplied with the kit.
Figure 17.
Electrical Cables
If these electrical cables are not hooked up properly the electric controller will be
damaged.
Important
If the Electric Power Swing will need to be moved from one tractor to another on a regular basis,
200 Amp booster-style cable clamps can be installed at the owner’s own risk and expense.
2. On the high end of the Power Swing remote receiver box, flip the power switch (
) to the ON
position.
Table 5.
Power Swing Receiver Box
Item
Description
1
Receiver Box
2
Power Switch
3
Direction switch
SWING-AWAY CONVEYOR – PORTABLE GRAIN BELT CONVEYOR