TROUBLESHOOTING
09.4
Troubleshooting
11-04
RoGator 418
Cabin
PROBLEM
POSSIBLE CAUSE
CORRECTION
Dust enters the cabin.
→
Improper seal around the
filter element.
→
Restricted filter.
→
Defective filter.
→
Excessive air leak(s) in cab
floor, windows, or door.
→
Pressurising fan not work-
ing.
→
Check seal condition.
→
Clean or replace the filter.
→
Replace the filter.
→
Seal air leak(s).
→
Repair the pressurising fan.
Pressurized air flow low.
→
Restricted filter.
→
Heater or vaporiser plugged.
→
Clean or replace the filter.
→
Contact Ag-Chem Europe
b.v. service centre.
Cab windows fog up
→
Excessive moisture in cab
air system.
→
Position the air vents toward
the windows. Use the air
conditioner system and re-
circulation control along
with the heating system to
dehumidify the cab air.
Heating system does not heat
→
Defective engine thermo-
stats.
→
Heater core is plugged.
→
Contact Ag-Chem Europe
b.v. se rvice centre.
→
Contact Ag-Chem Europe
b.v. se rvice centre.
Air conditioner does not cool
→
Condenser plugged.
→
Compressor belt slipping or
damaged.
→
Heater control turned on.
→
No air conditioning gas
→
Clean the radiator, the oil
cooling system and the con-
denser.
→
Check the tension and the
condition of the drive belt.
→
Turn the temperature knob
fully CCW for maximum
cooling.
→
Contact Ag-Chem Europe
b.v. se rvice centre.