MAINTENANCE
06.14
Maintenance
11-04
RoGator 418
1
3
2
4
Heat Exchangers
Clean the heat exchangers and the con-
denser of the air conditioning system
every 100 hours of operation. Use pres-
sure washer or compressed air.
Loosen the clamps of the engine hood and slide
the hood side ways. Clean the heat exchangers
and condenser with a pressure washer or com-
pressed air.
Heat Exchangers
1. Air Conditioner Condenser
2. Engine Radiator
3. Hydraulic Cooler
4. Charge Air Cooler
Electrical System
Electrical System Safety
DANGER
!
Ensure that not (fatal) injuries
occur when starting a driverless
vehicle. Do not start the engine
if the starter will cause a short
due to interchanged leads. The
engine will start normally if the
current is connected correctly.
Do NOT start the vehicle when
standing on the ground. Start
the vehicle only from the seat if
it is in neutral and the parking
brake is applied.
DANGER
!
The battery box involves dan-
gers. Do NOT attempt to change
a component in the battery box
except for the battery.
DANGER
!
Disconnect the battery terminals
before beginning to service the
electrical system.
DANGER
!
NEVER charge a frozen battery.
It could explode and cause se-
vere personal injury. Let the
battery warm up to 15 °C before
using a charger.
DANGER
!
NEVER use the battery box for
stowage purposes. Shorts and
explosions could result.
DANGER
!
Lead-acid batteries make flam-
mable and explosive gases.
Keep arcs, sparks, and flames
away. Never smoke near the
battery.
IMPORTANT: Do operate the vehicle with the
battery leads disconnected. Do use a fast
charger; do not perform any welding on the
RoGator with battery leads connected.
Batteries
Check that the battery leads are con-
nected correctly and are clean.
Turn off the battery disconnect switch
and remove any acid or corrosion on the
battery leads with a soda solution. To
prevent corrosion lubricated the terminals
with grease.
Inspect to see that the battery cables are
clean and tight.
Turn off the Battery Disconnection Switch
at the end of every working day.
Battery Disconnect Switch
Battery Terminal Connection
WARNING
!
Never charge a frozen battery. It
can explode and cause serious
personal injury. Let the battery
warm to15.5°C. (60°F) before
using a charger.
+
+
-
-