For AGCO part cross-reference visit: www.harvesttec.com/system.html
26
Tips & tip screen cleaning
: The spray shield assembly that holds the tips and tip screens is located above
the pickup head.
Before cleaning the tips and screens all personal protective equipment must be worn (Face shield or goggles,
chemically resistant apron, boots, and gloves).
Verify that the ball valve located next to the pump is turned off. Disconnect spray shield from hangers by
removing the lynch pins (A). Disconnect check valve nuts and remove hoses from shield. (B) Remove shield
from baler. Remove all six nozzle caps with a 7/8 inch wrench.(C) Hold the nozzle body from turning while
removing the nozzle caps with a 11/16 inch wrench. Remove the tip, and screen. Clean off any debris and
soak in warm water with a mild soap if necessary. Once the tips and screens are cleaned reinstall by following
the directions in reverse.
A
B
C