SERVICING - WARNING
Disconnect from electricity and gas before servicing. Check appliance is safe when you have finished.
51
Type 1
Unscrew the hexagonal nut in the front of the
regulator. The regulator nut has a plastic snap in
converter device on the underside, to convert the
regulator snap the device out of the nut and refit
the other way up.
set for Natural gas
set for Propane gas
The snap in converter device is marked to show
which gas it is set for. Make sure the device is
secure in the base of the nut and refit the nut to the
regulator.
Type 2
The regulator has a
bayonet mounted top
cap.
Using a small coin
press in and turn the
cap to remove it.
Turn the cap over so that the letters “LP” are visible
on base of the hollow in the cap. Refit the cap
making sure that the bayonet pins are securely
located.
Set for Natural gas
Set for Propane gas
Stick on label
Stick the appropriate label on to the data badge to
indicate the gas the appliance is now set for.
Pressure Testing
Connect the appliance to the gas supply. Check the
appliance is gas sound.
The gas pressure can be measured at the pressure
test point on the appliance side of the pressure
regulator.
Refit the storage drawer
To refit the drawer pull out the side runners. Rest
the drawer back on the side runners and, keeping it
level, push it right back. The clips should click into
position holding the drawer to the side runners.
Check the appliance is gas sound.
Check operation of all the burners.