54
Read all instructions before installing or using this appliance.
Installation Instructions
Save these instructions for future reference.
Ratings
Natural Gas
Propane Gas
Orifice Screw*
Orifice Screw*
Cooktop
Wok burner
15,000Btu/hr
internal 101
49
15,000Btu/hr
internal 59
49
external 167
external 94
Large Burner
12,000Btu/hr
170
38
12,000Btu/hr
106
38
Medium Burners
9,200Btu/hr
150 31
8,000Btu/hr
84 31
Small Burner
5,000Btu/hr
107 22
4,200Btu/hr
61 22
Gas burner inputs based on Gross Calorific Value
* The valves in this range are fitted with adjustable bypass screws. The range is supplied with the bypass screws set
for Natural gas. For LPG conversion the bypass screws must be screwed all the way down.
Ovens
Left hand Multifunction Oven
Right hand Fan Oven
Fan element
2.5kW
2.5kW
Top element
1.2kW
Browning Element
1.15kW
Bottom element
1.0kW
Broiler
2.3kW
Maximum total electrical load at 240V
approximate total including oven lights, oven fan etc: 7.4kW.
Orifices
A Wok burner
B Large Burner
C Medium Burners
D Small Burner
A valve bypass screw