58 Maintenance
4510012 - REV F – 220621
Carefully pull the Heating Element away from the Boiler Tank, preserving the orientation
of the Heating Element. The inside of the Boiler Tank should now be accessible.
Use water and a Long-Handled, Soft Wire Brush to scrape away any scale or sediment
buildup from inside the tank.
Staying aware of the orientation of the Heating Element and its Conductors, gently use
water and a Soft Wire Brush to remove foreign material from each Heat Element Coil
and Flange.
ATTENTION:
Do not use sharp force on the Heat Element Coils and
Flange, as this can damage them and potentially void the warranty.
Long-Handled,
Soft Wire Brush
Opening into
Boiler Tank
Long-Handled,
Soft Wire Brush
Heating
Element
Conductors
Heating
Element Coils
Содержание STC-WSN300-2M
Страница 1: ...WSN GEN S Steam Heat Shrink Tunnel User Guide ...
Страница 2: ...2 Abbreviations 4510012 REV F 220621 ...
Страница 8: ...8 Abbreviations 4510012 REV F 220621 ...
Страница 28: ...28 Introduction 4510012 REV F 220621 STC WSN600 2M GEN S Top View Front View Exit View Entry View ...
Страница 66: ...66 Troubleshooting 4510012 REV F 220621 ...
Страница 67: ...Electrical Schematics 67 4510012 REV F 220621 Electrical Schematics Complete System WSN GEN S ...
Страница 68: ...68 Electrical Schematics 4510012 REV F 220621 Boiler ...
Страница 72: ...72 Parts List 4510012 REV F 220621 Exploded Diagrams Stand Drawing Number YS130EX2 01 ...
Страница 74: ...74 Parts List 4510012 REV F 220621 Tunnel Drawing Number YS130EX2 02 ...
Страница 78: ...78 Parts List 4510012 REV F 220621 Boiler ...
Страница 79: ...Parts List 79 4510012 REV F 220621 Inside Boiler Electrical Cabinet ...
Страница 84: ...84 Technical Support 4510012 REV F 220621 ...