25
A setting that is locked will display a lock icon when viewed in the
basic level.
A locked setting is viewable in the basic programming menus but
it cannot be changed.
When viewing a setting in this level the display will show a "P”
value. This corresponds to the displayed setting.
Time & Day
Regen Time & Day
Salt Amount
P
Capacity
Hardness
P Value
SU
MO
TU
WE
TH
FR
SA
DAYS
Figure 34
Level II menus include:
P1 = Time of day
P2 = Day of week
P3 = Time of regeneration
P4 = Number of days between regeneration
P5 = Not used
P6 = Amount of regenerant used per regeneration or filter
backwash time
P7 = System capacity
P8 = Hardness
P9 = Units of measure
P10 = Clock mode
To enter Level II (Professional Programming) and change a setting:
Action
Key
Duration
Display
Enter Level II
programming
UP and
DOWN
5 sec.
P1 display
Return to
operation
UP and
DOWN
5 sec
Time and day of
week
Increment
through menus
UP and
DOWN
P/R
Next parameter
display
Enable setting
to be changed
SET
P/R
Parameter will
flash
Change value
UP and
DOWN
P/R
Value changes
Save setting
SET
P/R
Records value
and next
parameter is
displayed
English/Metric - P9 (Only accessed in Professional Level)
This setting is entered automatically at first power-up. The
North American controller will default to English units. The World
controller senses the electrical input and determines English or
metric units.
0 is English units. 1 is metric units. Use the arrow buttons to
change this setting. Press SET to accept the setting.
Time & Day
Regen Time & Day
Salt
P
Capacity
Hardness
SU
MO
TU
WE
TH
FR
SA
DAYS
Figure 35
12 Hour Clock / 24 Hour Clock - P10 (Only accessed
in Professional Level)
This setting is entered automatically at first power-up. The
North American controller will default to English units. The World
controller senses the electrical input and determines a 12- or 24-
hour clock. 0 is a 12-hour clock. 1 is 24-hour clock. Use the arrow
buttons to change this setting. Press SET to accept the setting.
Time & Day
Regen Time & Day
Salt Amount
P
Capacity
Hardness
SU
MO
TU
WE
TH
FR
SA
DAYS
Figure 36
Note:
Once SET is pressed in P10 the controller will change
to treated water (normal operation) mode. The time of day is
displayed and the colon is flashing.
Resetting the Control
To reset the control:
1. Press and hold SET and DOWN simultaneously for 5 seconds.
2. H0 and the system’s set resin volume (or “F” mode) will be
displayed. If a history value other than “H0” is displayed,
use the UP button to scroll through the settings until “H0” is
displayed.
3. To reset the control, press and hold SET for 5 seconds. The
control will be reset to an unprogrammed state.
4. Go to “Initial Set-up” section to reprogram control.
WARNING:
Resetting the control will delete
all information stored in its memory, except
time and day. This will require you to reprogram
the control completely from the initial power-up
mode.