22
Step 7: Estimated Capacity
• System capacity is displayed in total kilograins or kilograms
of hardness removed before a regeneration is necessary.
• Value is derived from the system’s resin volume input and
salt amount input.
• To change capacity on the control, press SET to make the
default capacity flash. Use the UP and DOWN buttons to
increment to the desired capacity.
KG
Time & Day
Regen Time & Day
Salt
Capacity
Hardness
SU
MO
TU
WE
TH
FR
SA
DAYS
Figure 29
Press SET to accept the setting and advance to the next
parameter.
Step 8: Enter Hardness
• Enter inlet water hardness at installation site.
• Default hardness setting is 10 grains (ppm for metric).
• To change hardness, press SET to make the setting flash.
Use the UP and DOWN buttons to scroll to the desired
hardness.
• Press SET to accept the entered hardness value.
• The control will return you to the normal operation mode.
Initial programming is now complete. The control will return to
normal operation mode if a button is not pushed for 30 seconds.
Time & Day
Regen Time & Day
Backwash Time
Capacity
Hardness
SU
MO
TU
WE
TH
FR
SA
DAYS
Figure 30
Placing Conditioner Into Operation
(Turning on the Water)
Conditioner Start-Up
After you have performed the previous initial power-up steps, you
will need to place the conditioner into operation. Follow these
steps carefully, as they differ from previous valve instructions.
WARNING:
Do not rotate the camshaft by
hand or damage to the unit may occur. Use the
controller to step the camshaft electronically
through the cycles.
1. Remove the cover from the valve. Removing the cover will
allow you to see that the camshaft is turning, and in which
cycle the camshaft is currently positioned.
2. With the supply water for the system still turned off, position
the bypass valve to the “not in bypass” (normal operation)
position.
3. Hold the REGEN button on the controller down for 5 seconds.
This will initiate a manual regeneration. The controller
will indicate that the motor is turning the camshaft to the
cycle C1 (Backwash) position by flashing an hourglass. The
controller will display the total regen time remaining. If you
press and hold the SET button, the controller will indicate the
time remaining in the current cycle.
Time & Day
Regen Time & Day
Salt
C
Capacity
Hardness
Flashing
SU
MO
TU
WE
TH
FR
SA
DAYS
Figure 31
4. Fill the media tank with water.
A. While the controller is in cycle C1 (Backwash), open
the water supply valve very slowly to approximately
the 1/4 open position.