Before turning on the water to the valve, rotate the two
handles on the bypass valve 2-3 times. This will help seat the
O-rings and prevent leaking.
If the plumbing to the conditioner is metal, a ground strap must be
installed.
The plumbing must be self supporting and secure to prevent
movement. A piece of metal or a ground strap is secured to both
the inlet and outlet pipes, Figure 10.
Figure 10 Grounding Strap
WARNING:
The inlet water must be
connected to the inlet port of the valve. When
replacing the valve, it is possible that the inlet
and outlet plumbing is installed in a reversed
position. Ensure that the plumbing is not
installed in the opposite order. Do not solder
pipes with lead-based solder.
WARNING:
Do not use tools to tighten
plastic fittings. Over time, stress may break the
connections. When the 1265 bypass is used,
hand tighten the nuts.
WARNING:
Do not use petroleum grease on
gaskets when connecting bypass plumbing.
Use only 100% silicone grease products when
installing any WC300 valve. Non-silicone grease
may cause plastic components to fail over time.
Installation Instructions
The system should be installed by someone familiar with
plumbing practices.
The conditioner is located after the pressure tank (or incoming
water supply) and any filtration equipment. Water that leaves
the conditioner will feed the hot water heater and the rest of the
building.
Place the conditioner and resin tank in position.
Use the plumbing adapters or the bypass and connect the valve
to the building plumbing. Be certain the water in and out valve
connections match the plumbing.
Connect the drain line. See Drain Line Connection.
Connect the regenerant line. See Regenerant Line Connection.
Connect the brine tank overflow. See Overflow Line Connection.
Plug in AC adapter to the control. Before loading regenerant or
applying power, review the sections on WC300 Controller, WC300
Series Initial Power Up, WC300 Advanced Programming, and
Placing the System Into Operation.
Plug the AC adapter into an electrical outlet that is not switched
on/off. The controller display will cycle to Level I Programming.
Refer to Initial Startup Step-by-Step Instructions for further startup
instructions.