36
A300 CS OPERATING MANUAL
© 2002 Design, 2014
Doc. No. 12-7287-r03 (7/14/14)
SET TMT MENU (NORM, GAUG)
, previously described on page 19.
SET ALARMS MENU (GAUG),
information includes (Fig. 64):
Selections with their last Set points saved include:
> AUDIBLE = with ON or OFF.
> DEPTH = with OFF, or 30 to 330 FT (or 10 to 100 M), increments of 10 FT (3 M).
> EDT = with OFF, or 0:10 to 3:00 (hr:min), increments of :05.
EDT is Elapsed Dive Time
.
> TURN = with OFF, or 1000 to 3000 PSI (or 70 to 205 BAR), increments of 250 PSI (5 BAR).
TURN is pressure of TMT 1
.
> END = with 300 to 1500 PSI (or 20 to 105 BAR), increments of 100 PSI (5 BAR).
END is pressure of the TMT in use
.
• A (< 2 sec) - to step forward (down screen) through and highlight Menu selections.
• M (< 2 sec) - to step back (up screen) through Menu selections.
• S (< 2 sec), when a selection is highlighted - to highlight & flash that item’s set point.
• A (< 2 sec) - to toggle or increase the set point.
• A (hold) - to increase the set point at a rate of 8 per second.
• M (< 2 sec) - to toggle or decrease the set point.
• S (< 2 sec) - to save the setting and revert to the Set Alarms Menu.
SET UTILITIES MENU (GAUG),
information includes (Fig. 65):
Selections with their last Set points saved include:
> WATER = with FRESH or SEA.
Depth values will be based on the type of water.
> UNITS = with IMPERIAL or METRIC.
> SAMPLING = with 2, 15, 30, or 60 SEC (second).
Rate that data is sampled and recorded for PC download.
Additional information relating to the effects of the items included are described in associated sections throughout this manual.
• A (< 2 sec) - to step forward (down screen) through and highlight Menu selections.
• M (< 2 sec) - to step back (up screen) through Menu selections.
• S (< 2 sec), when a selection is highlighted - to highlight & flash that item’s set point.
• A (< 2 sec) - to toggle or increase the set point.
• A (hold) - to increase the set point at a rate of 8 per second.
• M (< 2 sec) - to toggle or decrease the set point.
• S (< 2 sec) - to save the setting and revert to the Set Utilities Menu.
GAUG DIVE PREVIEW
,
information includes (Fig. 66):
Upon accessing this screen from the GAUG MENU, the items illustrated will be displayed with the settings last saved.
Turn and End Alarms will not be displayed unless a TMT is in use.
• S or M (2 sec) to step back to the GAUG MENU with VIEW PREVIEW highlighted.
Fig. 64 - SET ALARMS
Fig. 65 - SET UTILITIES
Fig. 66 - VIEW PREVIEW
GAUG SET ALARMS
AUDIBLE =
EDT =
TURN =
END =
DEPTH =
ON
150 FT
0:40
1500 PSI
300 PSI
GAUG SET UTILITIES
WATER =
SAMPLING =
UNITS =
15 SEC
FRESH
METRIC
DEPTH AL =
EDT AL =
TURN AL =
END AL =
WATER =
GAUG DIVE PREVIEW
150 FT
0:40
1500 PSI
300 PSI
FRESH
Содержание A300 CS
Страница 5: ...5 A300 CS OPERATING MANUAL 2002 Design 2014 Doc No 12 7287 r03 7 14 14 ACTIVATION and OVERVIEW...
Страница 11: ...11 A300 CS OPERATING MANUAL 2002 Design 2014 Doc No 12 7287 r03 7 14 14 HOME MODE...
Страница 16: ...16 A300 CS OPERATING MANUAL 2002 Design 2014 Doc No 12 7287 r03 7 14 14 NORM SURFACE MODE...
Страница 22: ...22 A300 CS OPERATING MANUAL 2002 Design 2014 Doc No 12 7287 r03 7 14 14 DIVE MODE FEATURES...
Страница 26: ...26 A300 CS OPERATING MANUAL 2002 Design 2014 Doc No 12 7287 r03 7 14 14 NORM DIVE MODE...
Страница 32: ...32 A300 CS OPERATING MANUAL 2002 Design 2014 Doc No 12 7287 r03 7 14 14 GAS TMT SWITCHING...
Страница 34: ...34 A300 CS OPERATING MANUAL 2002 Design 2014 Doc No 12 7287 r03 7 14 14 GAUG OP MODE...
Страница 38: ...38 A300 CS OPERATING MANUAL 2002 Design 2014 Doc No 12 7287 r03 7 14 14 FREE DIVE OP MODE...
Страница 43: ...43 A300 CS OPERATING MANUAL 2002 Design 2014 Doc No 12 7287 r03 7 14 14 COMPASS MODE...
Страница 48: ...48 A300 CS OPERATING MANUAL 2002 Design 2014 Doc No 12 7287 r03 7 14 14 NORM GAUG DIVE MODE ALARMS...
Страница 56: ...56 A300 CS OPERATING MANUAL 2002 Design 2014 Doc No 12 7287 r03 7 14 14 TECHNICAL DATA...
Страница 64: ...64 A300 CS OPERATING MANUAL 2002 Design 2014 Doc No 12 7287 r03 7 14 14 A300 CS DIVE COMPUTER OPERATING MANUAL...