19
A300 CS OPERATING MANUAL
© 2002 Design, 2014
Doc. No. 12-7287-r03 (7/14/14)
> Internally, the unit will keep track of the oxygen accumulation so that if FO2 for Gas 1 is subsequently set for Nitrox, the
oxygen accumulated during previous AIR dives will be accounted for in the next Nitrox dive (during that dive period and
series of repetitive dives).
FO2 set for Nitrox:
> When FO2 for any Gas is set for Nitrox (21 to 100%), the dive is calculated to be for Nitrox. The Nx icon will be dis-
played on all applicable screens.
> Once FO2 for Gas 1 is set for Nitrox (21 to 100%), the AIR option for all gases is disabled until 24 hours elapse after the
last dive.
> The AIR option will not be displayed in Set Gas until a full 24 hour Surface Interval has elapsed.
FO2 50% Default:
> When set ON and FO2 Gas 1 is set for Nitrox (21 to 100%), 10 minutes on the surface after that dive the FO2 for Gas 1
will be displayed as 50% and further dives will be calculated based on 50% O2 for oxygen calculations and 21% O2 for
Nitrogen calculations (79% Nitrogen), unless the FO2 for Gas 1 is changed before the dive.
> FO2 Gas 1 will continue to reset to the 50% Default after subsequent repetitive dives until 24 hours elapse after the last
dive, or the Default selection is set OFF.
> When the Default is set OFF, FO2 for Gas 1 will remain set at the last set point entered during that period of activation.
> If the Default is set OFF, FO2 for all gases will remain at their respective set points until changed.
> If the Default is set ON, FO2 for all gases default to 50%.
When the FO2 digits are highlighted & flashing (Fig. 28B):
• A (< 2 sec) - to step up through FO2 set points one at a time from AIR to 21 to 100% in increments of 1%.
• A (hold) - to scroll upward through the FO2 set points at a rate of 8 per second stopping momentarily at 32%, 50%, 80%,
and 100%, then at AIR or 21%.
• M (< 2 sec) - to step down through FO2 set points one at a time.
• S (< 2 sec) - to save the FO2 setting and highlight & flash the PO2 digits if Nitrox, or move to GAS 2 if AIR.
• S (2 sec) - to step back to & highlight the GAS # selected without changing the FO2 setting.
When the PO2 alarm digits are highlighted & flashing (Fig. 28C):
• A (< 2 sec) - to step up through the set points one at a time from 1.00 to 1.60 in increments of 0.05.
• M (< 2 sec) - to step down through the set points one at a time.
• S (< 2 sec) - to save the PO2 Alarm setting and step back to & highlight the GAS # selected.
• S (2 sec) - to step back to & highlight the FO2 value without changing the PO2 setting.
When the FO2 50% Default digits are highlighted & flashing:
• A or M (< 2 sec) - to toggle between OFF and ON 50%.
• S (< 2 sec) - to save the setting and step back to & highlight the graphic DEFAULT.
• S (2 sec) - to step back to & highlight the graphic DEFAULT without changing the setting.
SET TMT MENU (NORM, GAUG)
, information includes (Fig. 29A):
Selections with their last set points saved include (
SET will not be displayed upon access
):
> TMT 1 = with OFF or ON.
> TMT 2 = with OFF or ON.
> TMT 3 = with OFF or ON.
> TMT 4 = with OFF or ON.
• A (< 2 sec) - to step forward (down screen) through and highlight Menu selections.
• M (< 2 sec) - to step back (up screen) through Menu selections.
• S (< 2 sec), when a selection is highlighted - to highlight & flash that item’s set point.
• A (< 2 sec) - to step forward through that TMT’s set points (OFF, ON, & SET).
• M (< 2 sec) to step back through that TMT’s set points.
• S (< 2 sec) - to save the setting.
> If OFF is selected (saved), the A300 CS’s receiver will be disabled, all other TMT set selections will display the graphic
OFF, and operation will revert to the Set Utilities Menu.
> If ON is selected, ON becomes solid and the next TMT ON/OFF set point will flash, allowing it to be set.
> If SET is selected, the Set TMT Link Code screen will be displayed.
Set TMT Link Code (Serial Number)
, information includes (Fig. 29B):
>
Graphics TMT 1 (2, 3, 4) SERIAL NUMBER.
>
6 digit serial number, the 1st (left) digit flashing.
• A (< 2 sec) - to step upward through the 1st digit’s values.
• M (< 2 sec) - to step back through the 1st digit’s values.
• S (< 2 sec) - to save the 1st digit’s value and flash the 2nd digit.
•
Repeat A, M, S button action until all digits are set with operation then reverting to the Set TMT Menu with SET highlighted
allowing OFF or ON to be selected.
Fig. 29B - SET LINK CODE
Fig. 29A - TMT SET MENU
Fig. 28C - SET GAS MENU
(setting Gas 2 PO2 Alarm)
SET GAS MENU
GAS
1 =
32% ,
1.40
GAS
2 =
GAS
3 =
GAS
4 =
AIR
50% , 1.40
OFF
DEFAULT
= ON , 50%
MAX DEPTH
= 124 FT
SET GAS MENU
GAS
1 =
32%
,
1.40
GAS
2 =
GAS
3 =
GAS
4 =
AIR
50% , 1.40
OFF
DEFAULT
= ON , 50%
MAX DEPTH
= 124 FT
Fig. 28B - SET GAS MENU
(setting Gas 2 FO2)
SET TMT MENU
TMT
1 =
TMT
2 =
TMT
3 =
TMT
4 =
ON
OFF
OFF
SET
SET TMT LINK CODE
SERIAL NUMBER
0 3
9
9 5 6
TMT 2
Содержание A300 CS
Страница 5: ...5 A300 CS OPERATING MANUAL 2002 Design 2014 Doc No 12 7287 r03 7 14 14 ACTIVATION and OVERVIEW...
Страница 11: ...11 A300 CS OPERATING MANUAL 2002 Design 2014 Doc No 12 7287 r03 7 14 14 HOME MODE...
Страница 16: ...16 A300 CS OPERATING MANUAL 2002 Design 2014 Doc No 12 7287 r03 7 14 14 NORM SURFACE MODE...
Страница 22: ...22 A300 CS OPERATING MANUAL 2002 Design 2014 Doc No 12 7287 r03 7 14 14 DIVE MODE FEATURES...
Страница 26: ...26 A300 CS OPERATING MANUAL 2002 Design 2014 Doc No 12 7287 r03 7 14 14 NORM DIVE MODE...
Страница 32: ...32 A300 CS OPERATING MANUAL 2002 Design 2014 Doc No 12 7287 r03 7 14 14 GAS TMT SWITCHING...
Страница 34: ...34 A300 CS OPERATING MANUAL 2002 Design 2014 Doc No 12 7287 r03 7 14 14 GAUG OP MODE...
Страница 38: ...38 A300 CS OPERATING MANUAL 2002 Design 2014 Doc No 12 7287 r03 7 14 14 FREE DIVE OP MODE...
Страница 43: ...43 A300 CS OPERATING MANUAL 2002 Design 2014 Doc No 12 7287 r03 7 14 14 COMPASS MODE...
Страница 48: ...48 A300 CS OPERATING MANUAL 2002 Design 2014 Doc No 12 7287 r03 7 14 14 NORM GAUG DIVE MODE ALARMS...
Страница 56: ...56 A300 CS OPERATING MANUAL 2002 Design 2014 Doc No 12 7287 r03 7 14 14 TECHNICAL DATA...
Страница 64: ...64 A300 CS OPERATING MANUAL 2002 Design 2014 Doc No 12 7287 r03 7 14 14 A300 CS DIVE COMPUTER OPERATING MANUAL...