20
A300 CS OPERATING MANUAL
© 2002 Design, 2014
Doc. No. 12-7287-r03 (7/14/14)
SET ALARMS MENU (NORM),
information includes (Fig. 30):
Selections with their last Set points saved include:
> AUDIBLE = with ON or OFF.
> DEPTH = with OFF, or 30 to 330 FT (or 10 to 100 M), increments of 10 FT (3 M).
> EDT = with OFF, or 0:10 to 3:00 (hr:min), increments of :05.
EDT is Elapsed Dive Time
.
> TLBG = with 1 to 8 SEG, increments of 1 SEG.
SEG means Segments of the bar graph
> DTR = with OFF, or 1 to 0:20 ( :min), increments of :01.
DTR is Dive Time Remaining
.
> TURN = with OFF, or 1000 to 3000 PSI (or 70 to 205 BAR), increments of 250 PSI (5 BAR).
TURN is pressure of TMT 1
.
> END = with 300 to 1500 PSI (or 20 to 105 BAR), increments of 100 PSI (5 BAR).
END is pressure of the TMT in use
.
• A (< 2 sec) - to step forward (down screen) through and highlight Menu selections.
• M (< 2 sec) - to step back (up screen) through Menu selections.
• S (< 2 sec), when a selection is highlighted - to highlight & flash that item’s set point.
• A (< 2 sec) - to toggle or increase the set point.
• A (hold) - to increase the set point at a rate of 8 per second.
• M (< 2 sec) - to toggle or decrease the set point.
• S (< 2 sec) - to save the setting and revert to the Set Alarms Menu.
SET UTILITIES MENU (NORM),
information includes (Fig. 31A):
Selections with their last Set points saved include:
> WATER = with FRESH or SEA.
This adjusts depth values based on the type of water.
> UNITS = with IMPERIAL or METRIC.
> DEEP STOP = with OFF or ON. This only applies to No Deco dives.
> SAFE STOP = with OFF, ON, or TIMER. This only applies to No Deco dives.
> ALGORITHM = with DSAT or Z+.
This determines the basis for Ni-O2 calculations.
> CONSERV = with OFF or ON.
This, Conservative Factor, reduces NDLs based on altitude level.
> SAMPLING = with 2, 15, 30, or 60 SEC (second).
This is the rate that data is sampoled and recorded for PC download.
Additional information relating to the effects of the items included are described in associated sections throughout this manual.
• A (< 2 sec) - to step forward (down screen) through and highlight Menu selections.
• M (< 2 sec) - to step back (up screen) through Menu selections.
• S (< 2 sec), when a selection is highlighted - to highlight & flash that item’s set point.
• A (< 2 sec) - to toggle or increase the set point.
• A (hold) - to increase the set point at a rate of 8 per second.
• M (< 2 sec) - to toggle or decrease the set point.
• S (< 2 sec) - to save the setting and revert to the Set Utilities Menu.
Set Safety Stop
In addition to OFF, ON, and TIMER; Safe Stop has a SET selection
.
• S (< 2 sec), while SET is flashing - will display the Set Safe Stop Time/Depth screen with the Time setting flashing (Fig. 31B).
• A or M (< 2 sec) - to toggle TIME between 3 MIN and 5 MIN.
• S (< 2 sec) - to save the Time setting and flash the Depth digits.
• A (< 2 sec) - to step upward through Depth set points of 10, 15, 20 FT (or 3, 4, 5, 6 M).
• M (< 2 sec) - to step back through Depth set points.
• S (< 2 sec) - to save the setting and revert to the Set Utilities Menu with SET highlighted & flashing allowing OFF, ON, or
TIMER to be selected/saved (as described above).
SET PREVIEW (NORM),
information includes (Fig. 32):
Using this listing, you can chose up to 7 items (set points that have been entered) for display on a Preview screen that can be ac-
cessed from the NORM Menu (see page 16).
> FO2, PO2 alarms set for - Gas 1, 2, 3, 4.
> Alarm values set for - Depth, EDT, DTR, TLBG, Turn Pressure, End Pressure.
> Water Type selected
.
> Deep Stop seting
.
> Safety Stop setting
.
• A (< 2 sec) - to step forward (down 1st column then 2nd) through & highlight selections.
• M (< 2 sec) - to step back (up) through selections.
• S (< 2 sec) - when an item is highlighted will toggle* it between solid and flashing.
*Once 7 items are highlighted/flashing, another item cannot be toggled to be highlighted/flashing until one of the
highlighted/flashing items is toggled to solid, not highlighted first.
When satisfied that those items flashing (up to 4) are what you want for the Preview screen, press S (2 sec) to display all
items flashing, then press S (< 2 sec) to revert to the Menu with SET PREVIEW highlighted.
NORM SET ALARMS
AUDIBLE =
EDT =
TLBG =
DTR =
TURN =
END =
DEPTH =
ON
130 FT
0:40
8 SEG
0:10
1500 PSI
300 PSI
Fig. 30 - SET ALARMS
NORM SET UTILITIES
WATER =
DEEP STOP =
SAFE STOP =
ALGORITHM =
CONSERV =
SAMPLING =
UNITS =
TIMER
FRESH
IMPERIAL
OFF
DSAT
ON
15 SEC
Fig. 31A - SET UTILITIES
SET SAFE STOP
TIME =
3 MIN
DEPTH = 15 FT
Fig. 31B - SET NO DECO
SAFETY STOP
GAS
1
GAS
2
GAS
3
GAS
4
DEPTH AL
TLBG AL
TURN AL
END AL
WATER
DEEP STOP
SAFE STOP
EDT AL
DTR AL
NORM SET PREVIEW
Fig. 32 - SET PREVIEW
Содержание A300 CS
Страница 5: ...5 A300 CS OPERATING MANUAL 2002 Design 2014 Doc No 12 7287 r03 7 14 14 ACTIVATION and OVERVIEW...
Страница 11: ...11 A300 CS OPERATING MANUAL 2002 Design 2014 Doc No 12 7287 r03 7 14 14 HOME MODE...
Страница 16: ...16 A300 CS OPERATING MANUAL 2002 Design 2014 Doc No 12 7287 r03 7 14 14 NORM SURFACE MODE...
Страница 22: ...22 A300 CS OPERATING MANUAL 2002 Design 2014 Doc No 12 7287 r03 7 14 14 DIVE MODE FEATURES...
Страница 26: ...26 A300 CS OPERATING MANUAL 2002 Design 2014 Doc No 12 7287 r03 7 14 14 NORM DIVE MODE...
Страница 32: ...32 A300 CS OPERATING MANUAL 2002 Design 2014 Doc No 12 7287 r03 7 14 14 GAS TMT SWITCHING...
Страница 34: ...34 A300 CS OPERATING MANUAL 2002 Design 2014 Doc No 12 7287 r03 7 14 14 GAUG OP MODE...
Страница 38: ...38 A300 CS OPERATING MANUAL 2002 Design 2014 Doc No 12 7287 r03 7 14 14 FREE DIVE OP MODE...
Страница 43: ...43 A300 CS OPERATING MANUAL 2002 Design 2014 Doc No 12 7287 r03 7 14 14 COMPASS MODE...
Страница 48: ...48 A300 CS OPERATING MANUAL 2002 Design 2014 Doc No 12 7287 r03 7 14 14 NORM GAUG DIVE MODE ALARMS...
Страница 56: ...56 A300 CS OPERATING MANUAL 2002 Design 2014 Doc No 12 7287 r03 7 14 14 TECHNICAL DATA...
Страница 64: ...64 A300 CS OPERATING MANUAL 2002 Design 2014 Doc No 12 7287 r03 7 14 14 A300 CS DIVE COMPUTER OPERATING MANUAL...