Doc. No. 12-7287-r03 (7/14/14)
battery.Indication:
• Good (> 2.75 v) >> BATT Icon (green) solid on Surface and Dive Mains.
No restrictions surface or dive..
• Warning (<= 2.75 v) >> BATT Icon (yellow) solid on Surface and Dive Mains, Battery change recommended.
Brightness level automatically limited to
60% maximum.
• Alarm (<= 2.50 v) >> BATT Icon (red) flashing on Surface and Dive Mains. Graphics GO UP LOW BATTERY with Up Arrows flashing on Dive Mains,
graphics CHANGE BATTERY (red) flashing on Surface Mains until the unit the shuts off.
Must change the Battery.
Transmitter.battery.Indication:
• Warning (<= 2.75 v) >> graphic BATT LOW (yellow) solid on BATT, TMT STATUS screen, Battery change recommended.
• Alarm (<= 2.50 v) >> graphic TMTx LOW BATTERY (red) alternating with graphic NORM (or GAUG, or FREE) on Surface Main.
Change the Battery.
• Alarm (<= 2.50 v) >> graphic BATT LOW (red) flashing on BATT, TMT STATUS screen.
Change the Battery.
Operating.Temperature:
• Out of the water >> between 20 °F and 140 °F (-6 and 60 °C).
• In the water >> between 28 °F and 95 °F (-2 and 35 °C).
bAR.GRAPHS:
TLbG
segments
.
• No Deco Normal zone 1 to 6 (green)
• No Deco Caution zone 7 to 9 (yellow)
• Decompression zone 10 (red)
VARI
60 FT (18 M) & Shallower Deeper than 60 FT (18 M)
segments
FPM MPM segments FPM
MPM
0
0 - 10 0 - 3 0 0 - 20
0 - 6
• Normal zone (green) 1
11 - 15 3.5 - 4.5 1 21 - 30 6.5 - 9
Normal zone (green) 2
16 - 20 5 - 6 2 31 - 40 9.5 - 12
Normal zone (green) 3
21 - 25 6.5 - 7.5 3 41 - 50 12.5 - 15
• Caution zone (yellow) 4
26 - 30 8 - 9 4 51 - 60 15.5 - 18
• Too Fast zone (red) 5 (all flash) > 30 > 9 5 (all flash) > 60 > 18
NUMERIC.DISPLAYS:.
Range:
Resolution:
• Time of Day
0:00 to 23:59 hr:min
1 minute
• PC/Mac Countdown Timer
2:00 to 0:00 min:sec
1 second
• Altitude Level
Sea, EL-2 to EL-7
1 (level)
• Time to Fly
23:50 to 0:00 hr:min
1 minute
• Time to Desaturate
23:50 to 0:00 hr:min
1 minute
• Temperature
0 to 99°F (-18 to 60°C)
1°F (C)
• Depth, Max Depth (display)
0 to 330 FT (100 M)
1 FT (0.1 M )
• Tank Pressure
0 to 5000 PSI (345 BAR)
5 PSI (1 BAR)
• NORM, GAUG Surface Interval
0:00 to 23:59 hr:min
1 minute
• NORM, GAUG Dive Number
0 to 24
1 (dive)
• NORM, GAUG Log Entry Number
0 to 99
1 (dive)
• NORM, GAUG Elapsed Dive Time
0:00 to 9:59 hr:min
1 minute
• NORM Dive Time Remaining
0:00 to 9:59 hr:min
1 minute
• NORM, GAUG Air Time Remaining
0 to 99 min
1 minute
• FO2 Set Point (Gas 1, 2, 3, 4)
Air, 21 to 100 %
1 %
• PO2 (current value)
0.00 to 5.00 ATA
.01 ATA
• O2 Saturation
0 to 100 %
1 %
• No Deco Deep Stop Time
2:00 to 0:00 min:sec
1 second
• No Deco Safety Stop Time
5:00 to 0:00 min:sec
1 second
• No Deco Safety Stop Run Timer
0:00 to 9:59 min:sec
1 second
• GAUG Dive Run Timer
0:00 to 9:59 min:sec
1 second
0:10 to 9:59 hr:min
1 minute
• Deco Stop Time
0:00 to 9:59 hr:min
1 minute
• Deco Total Ascent Time
0:00 to 9:59 hr:min
1 minute
• Violation Countdown Timer
23:50 to 0:00 hr:min
1 minute
SPECIfICATIONS (CONTINUED)
Содержание A300 CS
Страница 5: ...5 A300 CS OPERATING MANUAL 2002 Design 2014 Doc No 12 7287 r03 7 14 14 ACTIVATION and OVERVIEW...
Страница 11: ...11 A300 CS OPERATING MANUAL 2002 Design 2014 Doc No 12 7287 r03 7 14 14 HOME MODE...
Страница 16: ...16 A300 CS OPERATING MANUAL 2002 Design 2014 Doc No 12 7287 r03 7 14 14 NORM SURFACE MODE...
Страница 22: ...22 A300 CS OPERATING MANUAL 2002 Design 2014 Doc No 12 7287 r03 7 14 14 DIVE MODE FEATURES...
Страница 26: ...26 A300 CS OPERATING MANUAL 2002 Design 2014 Doc No 12 7287 r03 7 14 14 NORM DIVE MODE...
Страница 32: ...32 A300 CS OPERATING MANUAL 2002 Design 2014 Doc No 12 7287 r03 7 14 14 GAS TMT SWITCHING...
Страница 34: ...34 A300 CS OPERATING MANUAL 2002 Design 2014 Doc No 12 7287 r03 7 14 14 GAUG OP MODE...
Страница 38: ...38 A300 CS OPERATING MANUAL 2002 Design 2014 Doc No 12 7287 r03 7 14 14 FREE DIVE OP MODE...
Страница 43: ...43 A300 CS OPERATING MANUAL 2002 Design 2014 Doc No 12 7287 r03 7 14 14 COMPASS MODE...
Страница 48: ...48 A300 CS OPERATING MANUAL 2002 Design 2014 Doc No 12 7287 r03 7 14 14 NORM GAUG DIVE MODE ALARMS...
Страница 56: ...56 A300 CS OPERATING MANUAL 2002 Design 2014 Doc No 12 7287 r03 7 14 14 TECHNICAL DATA...
Страница 64: ...64 A300 CS OPERATING MANUAL 2002 Design 2014 Doc No 12 7287 r03 7 14 14 A300 CS DIVE COMPUTER OPERATING MANUAL...