41
A300 CS OPERATING MANUAL
© 2002 Design, 2014
Doc. No. 12-7287-r03 (7/14/14)
fREE DIVE MAIN,
information includes (Fig. 80A/B) -
Either Elapsed Dive Time (EDT) or the Countdown Timer (CDT) can displayed on the Main screen with the other on the Alternate.
Due to short dive times, the Auto Dim feature that automatically dims the screen to a lower level of brightness is not active during FREE dives. Bright-
ness will remain at the % you adjust it to until you change it.
> BATT icon - green (if battery voltage is good), or yellow (if at warning level), or red (if at alarm level).
> Current Depth with FT (or M) icon.
> Graphic EDT with Elapsed Dive Time (up to 9:59 min:sec), or graphic CDT with Countdown Time (from min:sec set to 0:00).
> Temperature with F (or C) icon.
> TLBG (TL), if any from FREE or previous NORM dives.
• A (2 sec) - to access Adjust Brightness.
• A (< 2 sec) - to access ALT.
• S (< 2 sec) - to interchange EDT and the CDT, prevented during alarm strikes.
• M (< 2 sec) - to start/stop CDT, only while it is on the Main.
• S (< 2 sec) - to acknowledge alarms.
• S (2 sec) - to access Compass*.
*These items can only be accessed while viewing the Main.
ADJUST BRIGHTNESS
, information includes (Fig. 81):
> xx % (last value saved).
Up to 60% max when Low Battery Warning or Alarm.
• S (2 sec) - to step back to the Main without changing the value.
• A (< 2 sec) - to step upward through values of 10% to 100% one at a time in increments of 10%.
• M (< 2 sec) - to step down through values one at a time.
• S (< 2 sec) - to save the % setting and revert to the Main.
• Revert to Main in 10 sec, if no button is pressed.
fREE DIVE ALT,
information includes (Fig. 82A/B) -
> RUN TIME = min:sec (from setting to 0:00), or EDT = min:sec (up to 9:59).
> MAX D = xxx FT (or xx.x M).
> TIME = hr:min with AM (or PM) if 12 Hour Format.
> NDC = hr:min (up to 9:59).
• A or M (< 2 sec) - to step back to FREE Dive Main.
• Revert to Main in 10 sec, if no button is pressed.
fREE DIVE ALARMS
FREE mode alarms, which are separate from NORM (or GAUG) alarms, sound 1 or 3 times as (3) short beeps then clear. They
cannot be acknowledged or silenced.
fREE CDT Alarm
When a set Countdown Time reaches 0:00, the Audible Alarm will sound during which time the graphic CDT with 0:00 (yellow)
will flash on the Dive Main screen* (Fig. 83A), then remain as 0:00 solid. *
If EDT was selected and displayed on the Main, it
will be replaced by CDT during the audible then EDT will be restored when the audible is silenced.
fREE RTI (EDT) Alarm
When set ON, the RTI (Repeating Time Interval) alarm activates every 30 seconds of EDT (Elapsed Dive Dive) during a dive. The
Audible will sound during which time the graphic EDT with Time digits (yellow) will flash on the Dive Main screen* (Fig. 83B),
then the screen will return to normal. *
If CDT was selected and displayed on the Main, it will be replaced by EDT during the
audible then CDT will be restored when the audible is silenced.
fREE Depth Alarms
When set ON, the Depth alarms (1, 2, 3) activate at their set Depths. The Audible will sound during which time the graphic D1
(D2, D3) and Depth digits (yellow) will flash on the Dive Main screen (Fig. 83C), then return to normal.
High Nitrogen Alarms
When nitrogen increases to the caution level (9 segments), the Audible will sound during which time the TLBG segments (green &
yellow) will flash on the Dive Main screen (Fig. 83D), then become solid.
In the event that nitrogen continues to increase and reaches the Deco level; the Audible will sound again during which all TLBG
segments and the graphics GO UP VIOLATION with Up Arrows will flash on the Dive Main screen until on the surface (Fig. 83E).
The TLBG will be removed after the audible is silenced.
Upon surfacing, the graphic VIOL (red) will flash for 1 minute, then alternate with FREE for 24 hours with VGM (Violation Gauge
Mode) activated to prevent further dives.
Fig. 80A - FREE DIVE MAIN
(EDT selected)
Fig. 81 - BRIGHTNESS
Fig. 83B - EDT ALARM
Fig. 83C - DEPTH ALARM
Fig. 83D - TLBG AL
Fig. 83E - VIOLATION
(entry into Deco)
Fig. 83A - CDT ALARM
25
FT
3:02
CDT
F
76
TL
BATT
46
FT
1:26
EDT
F
78
TL
BATT
Fig. 80B - FREE DIVE MAIN
(CDT selected)
100%
ADJUST BRIGHTNESS
CDT =
TIME =
NDC =
MAX D =
3:02
78 FT
10:26 AM
1:19
EDT =
TIME =
NDC =
MAX D =
1:26
78 FT
10:26 AM
1:19
Fig. 82B - FREE DIVE ALT
(CDT is on Main)
Fig. 82A - FREE DIVE ALT
(EDT is on Main)
60
FT
2:24
CDT
F
63
TL
D1
BATT
46
FT
0:00
CDT
F
83
TL
BATT
28
FT
1:30
EDT
F
67
TL
BATT
106
FT
2:18
EDT
F
59
TL
BATT
78
FT
F
54
TL
GO UP
VIOLATION
BATT
Содержание A300 CS
Страница 5: ...5 A300 CS OPERATING MANUAL 2002 Design 2014 Doc No 12 7287 r03 7 14 14 ACTIVATION and OVERVIEW...
Страница 11: ...11 A300 CS OPERATING MANUAL 2002 Design 2014 Doc No 12 7287 r03 7 14 14 HOME MODE...
Страница 16: ...16 A300 CS OPERATING MANUAL 2002 Design 2014 Doc No 12 7287 r03 7 14 14 NORM SURFACE MODE...
Страница 22: ...22 A300 CS OPERATING MANUAL 2002 Design 2014 Doc No 12 7287 r03 7 14 14 DIVE MODE FEATURES...
Страница 26: ...26 A300 CS OPERATING MANUAL 2002 Design 2014 Doc No 12 7287 r03 7 14 14 NORM DIVE MODE...
Страница 32: ...32 A300 CS OPERATING MANUAL 2002 Design 2014 Doc No 12 7287 r03 7 14 14 GAS TMT SWITCHING...
Страница 34: ...34 A300 CS OPERATING MANUAL 2002 Design 2014 Doc No 12 7287 r03 7 14 14 GAUG OP MODE...
Страница 38: ...38 A300 CS OPERATING MANUAL 2002 Design 2014 Doc No 12 7287 r03 7 14 14 FREE DIVE OP MODE...
Страница 43: ...43 A300 CS OPERATING MANUAL 2002 Design 2014 Doc No 12 7287 r03 7 14 14 COMPASS MODE...
Страница 48: ...48 A300 CS OPERATING MANUAL 2002 Design 2014 Doc No 12 7287 r03 7 14 14 NORM GAUG DIVE MODE ALARMS...
Страница 56: ...56 A300 CS OPERATING MANUAL 2002 Design 2014 Doc No 12 7287 r03 7 14 14 TECHNICAL DATA...
Страница 64: ...64 A300 CS OPERATING MANUAL 2002 Design 2014 Doc No 12 7287 r03 7 14 14 A300 CS DIVE COMPUTER OPERATING MANUAL...