25
5.1 - Choosing the
installation location
WARNING!!!
Do not
store any flammable materials
or liquids in the immediate
vicinity of the heater. A fire or
explosion can result, causing
severe personal injury, death, or
substantial property damage.
WARNING!!!
Do not install
the heater on carpeting. Fire can
result, causing severe personal
injury, death, or substantial
property damage.
WARNING!!!
Provisions for
combustion air and ventilation
of the heater room are always
required, regardless whether
the combustion air is taken from
the outside (Direct Vent, sealed
combustion) or inside (room
air for combustion). Failure to
comply with this provision could
result in excessive levels of
carbon monoxide or a fire, which
can result in severe personal
injury or death!
WARNING!!!
Insufficient
ventilation of the heater
room can lead to high air
temperatures. Failure to comply
with this provision could result
in excessive levels of carbon
monoxide or a fire, which can
result in severe personal injury
or death!
WARNING!!!
Make
sure that intake and exhaust
openings are sufficiently sized
and no reduction or closure of
openings takes place. When
the problem is not resolved, do
not operate the heater. Please
note these restrictions and its
dangers to the operator of the
heater. Failure to comply with
this provisions could result in
severe personal injury, death, or
substantial property damage.
5 - INSTALLATION - Location
WARNING!!!
LIQUEFIED
PETROLEUM (L.P.) PROPANE
GAS-FIRED HEATER LOCATION
REQUIRES SPECIAL
ATTENTION: 1994 UNIFORM
MECHANICAL CODE, section
304.6: “LPG Appliances.
Liquefied petroleum gas-burning
appliances shall not be installed
in a pit, basement or similar
location where heavier-than-air-
gas might collect. Appliances
so fueled shall not be installed
in an abovegrade under-floor
space or basement unless such
location is provided with an
approved means for removal
of unburned gas.” Failure to
comply with this provision could
result in and explosion that can
cause severe personal injury,
death, or substantial property
damage.
CAUTION!!!
This heater is not
designed for direct outdoor
installation. If installed outside of
the structure, it must be sheltered
so it is protected from rain, wind,
sun and frost. NEVER place this
heater in a location that would
subject it to temperatures at or near
freezing or temperature that exceed
100°F (38°C). Failure to properly
locate this heater can result in
premature failure.
CAUTION!!!
This heater must
be installed in a location so
that any water leaking from the
heater or piping connections
or relief valve openings will
not cause damage to the area
surrounding the unit or any
lower floors in the structure.
CAUTION!!!
When installed in a
room with thin floor, resonating
noise may occur. Install noise
reducing parts if required.
CAUTION!!!
Do not allow too
much dust to collect on the
heater.
Maintain minimum specified clearances
for adequate operation. All installations
must allow sufficient space for servicing
the vent connections, water pipe
connections, piping and other auxiliary
equipment, as well as the appliance.
The clearance labels on each appliance
note the same service and combustible
clearance requirements as shown on
section 5.4 and 5.5.
Multiple appliances may be installed in
a modular heater installation.
Consult the venting section of this
manual for specific installation
instructions for the appropriate type of
venting system that you will be using.
Direct vent and vent/air venting systems
require installation with
Category IV
flue pipe, sealed air inlet pipe, and
air inlet caps, which must meet the
manufacturer’s specifications.
Combustion and ventilation air
requirements for appliances drawing
air from the equipment room.
Provisions for combustion and
ventilation air must be in accordance
with air for combustion and ventilation,
of the latest edition of the National Fuel
Gas Code, ANSI Z223.1, in Canada,
the latest edition of CGA Standard
B149 Installation Code for Gas
Burning Appliances end Equipment,
or applicable provisions of the local
building codes.
Содержание Esteem 399
Страница 3: ...3 SAFETY INSTRUCTIONS ...
Страница 5: ...5 SAFETY INSTRUCTIONS ...
Страница 112: ...112 17 MAINTENANCE ...
Страница 116: ...116 19 SPARE PARTS Spare parts ...
Страница 135: ......