OPERATION
Table 3-1. BMS II Front Panel Controls and Displays
ITEM
NO.
CONTROL, INDICATOR
OR DISPLAY
FUNCTION
1
VFD Display
The Vacuum Fluorescent Display (VFD) display consists of 2
lines each capable of displaying up to 16 alphanumeric
characters. The information displayed includes:
•
Startup
Messages
•
Alarm
Messages
•
Operating
Status
Messages
•
Menu
Selections
2
FAULT
Indicator Red
FAULT
LED indicator lights when a BMS II alarm
condition occurs. An alarm message will also appear in the
VFD display.
3
CLEAR
Key
Turns off the
FAULT
indicator and relay if FAULT ALRM
CLEAR is set to Manual and the fault is still active or no
longer active. If FAULT ALRM CLEAR is set to Automatic
and the fault is still active, this will also turn off the fault relay
and indicator. In both cases the alarm message will remain
until the alarm is no longer valid.
4
MENU Keypad
Consists of 6 keys which provide the following functions for
the BMS II menus:
MENU
Steps through the main menu categories shown in Figure 2-1.
The Menu categories wrap around in the order shown.
BACK
Allows you to go back to the previous menu level without
changing any information. Continuously pressing this key will
bring you back to the default status display in the Operating
Menu. Also, this key allows you to go back to the top of a
main menu category.
▲
(Up) Arrow
When in one of the main menu categories, pressing this key
will move you forward through the displayed menu category.
If the
CHANGE
key was pressed and the menu item is
flashing, press the
▲
arrow key increment the setting.
▼
(Down) Arrow
When in one of the main menu categories, pressing this key
will select the displayed menu category. If the
CHANGE
key
was pressed and the menu item is flashing, pressing the
▼
(Down) arrow key will decrement the selected setting.
CHANGE
Permits a setting to be changed (edited). A valid password
must be entered before changing most menu items. When
the
CHANGE
key is pressed, the displayed menu item will
alternate in color with the background (reverse video).
Pressing the
▲
or
▼
arrow key when this occurs will
increment or decrement the displayed setting.
ENTER
Saves the modified menu information in memory. The
display will return to the normal state.
5
ON/OFF
Key
Enables and disables BMS II operation.
6
ON
Indicator Green
ON
LED lights when the BMS II is enabled.
3-2
Содержание BOILER MANAGEMENT SYSTEM II 5R5-384
Страница 8: ......
Страница 12: ......
Страница 16: ...INSTALLATION ...
Страница 17: ...INSTALLATION 2 5 ...
Страница 21: ...INSTALLATION ...
Страница 32: ...OPERATION Figure 3 2 BMS II Menu Structure 3 4 ...