- 35 -
TSE-N 10.00 A. B.
599 50 84 90
EN
L D9
L D10
L D11
27. Rinse, resin wash, regeneration and measure
rinse
-
Always when activating the circulation pump and/or the interheater, refilling of water is
enabled.
o
But the maximum refill time is limited to 60 seconds.
o
Exceeding this limit causes a failure code display and the program cycle is
stopped.
PPD-LED LD9 is blinking.
measure to cleaner and rinse aid
-
The activation times of the dispenser were optimised with the EDW1000:
o
In program phase cleaning
30 seconds ON
o
In program phase hot rinse
30 seconds ON / 30 seconds OFF / 30 seconds ON
The dosage of rinse aid is temperature controlled at a minimum of 50°C.