- 32
-
TSE-N
10.00
A.
B.
599
50
84
90
EN
24.
Overview
of
failure
displays
)DLOXUH
'LVSOD\
33'/('V
Failure display
visible
for customer
Visible in failure
memory
(After sales)
6KRUWGHVFULSWLRQ
Closed water tap
yes
blinking
yes
highlighted
Timeout for filling - Failure recognised if ...
1) ... after 2 min of static filling ...
2) ... after 4 min of total filling ...
3) ... after 1 min of dynamic refilling during heating phase ...
... the switch point of the pressure switch wasnt reached.
Drain pump
yes
blinking
yes
highlighted
Pressure switch didn’t reach the switch back after 2 drain cycles.
Aqua-Control
yes
blinking
yes
highlighted
Floating switch detects water in the bottom tray
(Debounce time 2sec.)
Heating
no
yes
highlighted
Target temperature not reached after a timeout of 45 min.
(Only possible in temperature controlled heating steps)
NTC-Sensor
no
yes
highlighted
NTC short circuit or interrupt.
The NTC is controlled between the 1st filling and the start of the
drying cycle
Tacho
yes
blinking
yes
highlighted
After activating the circulation pump, within 30 sec no signal from
the tachometer is recognised.
Circulation pump
Triac short circuit
yes
blinking
yes
highlighted
Signal from tachometer is recognised, although the circulation
pump isn’t activated.
Wrong variant
programming
no
display
no
no
not possible
Checksum in EEProm not correct.
Only recognised after switching ON.
L D9
L D10
L D11
L D9
L D10
L D11
L D9
L D10
L D11
L D9
L D10
L D11
L D9
L D10
L D11
L D9
L D10
L D11
L D9
L D10
L D11
:KDWKDSSHQV"
Progr.-LED blinking. Program stopped.
After removing the failure, the program can be continued
bei pressing button S0 (OFF-ON).
Progr.-LED blinking. Program stopped.
After removing the failure, the program can be continued
bei pressing button S0 (OFF-ON).
Program interrupted.
Inlet valve closed and drain pump activated for 1 drain cycle
(approx. 1min).
After removing the failure, the program can be continued
bei pressing button S0 (OFF-ON).
Program is terminated without activation of the heating
element!
All heating steps last 45min in general.
Program is terminated without activation of the heating
element!
All heating steps last 45min in general.
The program is interrupted.
By pressing the button S0 (OFF-ON), the program can be
restarted.
(Failure repeatedly occuring
Õ
Service call)
The program is interrupted and water filled till the switch
oint of the pressure switch.
By pressing the button S0 (OFF-ON), the program can be
restarted.
(Failure repeatedly occuring ð Service call)
No program selection possible
On/Off-lamp (LD0) on