- 16 -
TSE-N 10.00 A. B.
599 50 84 90
EN
Circulation
The circulation pump (17) pumps the water simultaneously into the ceiling shower (22) and into both
spray arms (21). The water is filtered in the sieves (16) and led to the circulation pump.
Function of the new pulse wash with random functionality
After the filling steps, the circulation pump is running at two rotational speeds.
Random function
T
high,r
=
time for high speed (calculated with random funktion)
T
high
=
time for high speed (cycle definition)
T
r
=
random time
T
low
=
time for low speed
Ratio
=
factor for low speed (eeprom definition)
The ratio of pulse time and pause is always 1 : 5.
3XOVH:DVK
8VHZLWK:DVK&\FOHV
'HILQLWLYH7LPH 5DQGRP7LPH 'HILQLWLYH7LPH 5DQGRP7LPH
1
0.9 sec
0 - 0.3 sec
4.5
0 - 1.5 sec
prewash intensive
wash intensive
2
0.6 sec
0 - 0.3 sec
3
0 - 1.5 sec
wash and intermediate wash
prewash normal
3
0.3 sec
0 - 0.3 sec
1.5
0 - 1.5 sec
rinse
3XOVHWLPHPLQ
3DXVHPLQ
T
high, r
=
T
high
+ T
r
T
low
=
T
high, r
+ Ratio