14 www.electrolux.com
• Secure the wrapped piping along
the exterior wall using saddle or
equivalent.
Fig.3.4.3-1
3.
In cases where the outdoor unit is
installed above the indoor unit level:
• Wrap the piping and connecting
cable from the down to up.
• Form a trap to prevent water from
entering the room.
• Secure the wrapped piping along
the exterior wall using saddle or
equivalent.
Fig.3.4.3-2
Seal small openings
around piping with
a gum type sealer
Trap is required to prevent water
from entering into electrical parts
Wrapping
Pipe
Drain
hose
Connection
cable
Drain hose
Seal small openings
around piping with
a gum type sealer
Trap
Trap
Drain hose
3.4.4
Checking the Drainage
1.
Open and lift the indoor unit front
panel.
• Hold the lower part of the left and
right sides of the panel, pull it
against you and lift it stops with
support.
Fig.3.4.4-1
2.
Check the drainage
• Carefully pour a glass of water on
the evaporator.
•
Ensure the water flows through the
drain hose of the indoor unit without
any leakage and goes out the drain
exit.
Fig.3.4.4-2
3.
Dain piping
• The drain hose should point
downward for easy drain flow.
Drain
hose