10 www.electrolux.com
3.
Install the unit at the site where it is
exposed to as little wind as possible,
especially not in areas where it is
frequently windy.
4.
If the installation site is exposed to
heavy winds, such as in coastal areas,
place the unit along the widest part of
the wall or use protective plates.
5.
Be sure there is no obstacle which
blocks exhausting air, including shrubs
or bushes.
Fig.3.2.1-1
NOTE:
• Settlement of outdoor unit. Anchor the
outdoor unit tightly and horizontally
on a concrete or flat mount with a bolt
and nut 10mm diameter (Purchased
separately).
Fig.3.2.1-2
Strong Wind
Air Inlet
Air Inlet
Air Outlet
3.2.2
Condensate drainage of
outdoor unit (only for heat
pump model)
1.
During heating operation, the
condensate and defrosting water
should be drained out reliably through
the drain hose.
2.
Install the outdoor drain connector in
the drain-water hole on the chassis of
outdoor unit, and attach the drain hose
to the connector so that the waste
water formed in the outdoor unit can
be drained out.
3.
The drain-water hole must be plugged.
Whether to plug other holes will be
determined by the installer according
to actual conditions.
4.
In case of a drain hose, the unit must
be installed on a base more than 3cm
height.
Fig.3.2.2
NOTE:
• For some heat pump models, no drain
connecter provided due to enough
drain-water hole designed.
3.3
Refrigerant piping
connection
NOTE:
• Keep original bend so no kinking of the
tube occurs.
Drain
connecter
Hose
(not provided)
Chassis
Drain-water
hole