13
ENGLISH
3.
Hang the indoor unit:
• Remove the spacer.
• Hook the indoor unit onto the
upper portion of the mounting plate
(Engage the hooks of the mounting
plate into the openings at the rear
top of the indoor unit).
• Ensure that the hooks are properly
seated on the mounting plate
by moving the indoor unit in all
directions.
Fig.3.4.1-8
• Press the lower left and right sides
of the unit against the mounting
plate until the hooks engage into
their slots (clicking sound).
Fig.3.4.1-9
3.4.2
Outdoor Unit
1.
Align the centers of the pipes and
sufficientlytighten the flare nut with
your hands.
Upper hook
Mounting
plate
Spacer
Upper hook
Connecting
cable
Drain hose
Mounting plate
Fixing lower hook
Fig.3.4.2-1
2.
Then, tighten the flare nut with torque
wrenchuntil the wrench clicks.
Fig.3.4.2-2
ZD\
YDOYH
• Make sure to follow the torque table
value as below table:
2XWHUGLDP
PP
7RUTXH
1P
$GGLWLRQDO
7RUTXH1P
̻ರ
NJP NJP
̻ರ
NJP NJP
̻ರ NJP NJP
̻ರ NJP NJP
3.4.3
Piping Formation
1.
Form the piping by wrapping the
connecting portion of the indoor unit
with insulation material and secure it
with narrow vinyl tape and wide vinyl
tape.
• If you want to connect an additional
drain hose, the end of the drain
hose outlet should be routed above
the ground. Secure the drain hose
appropriately.
2.
In cases where the outdoor unit is
installed below the indoor unit level:
• Wrap the piping, drain hose and
connecting cable from the down
to up.
Liquid
pipe
Outdoor Unit
Suction
pipe
3-way valve