USER'S GUIDE
OPERATING MODES
PK232UG Rev. B 9/86
4-34
87
o If
DAYSTAMP
is
OFF
,
CONSTAMP
and
MSTAMP
show only
TIME
.
o If
DAYSTAMP
is
ON
, the
DATE
is included in
CONSTAMP
an
MSTAMP
.
Set
DAYSTAMP ON
when you want a dated record of Packet channel activity, or when
you're unavailable for local Packet operation.
4.6.12.7
DAYTIME
– Set the Real-Time Clock
You can activate the PK-232's real-time clock by setting the date and time with the
command
DAYTIME
. Once you have set the clock, you can request the time by entering
DAYTIME
with no parameters. If you have turned off your PK-232 since the last time
you entered
DAYTIME
,
DAYTIME
will have to be reset.
The clock is not set when the PK-232 is turned on. The DAYTIME command will display
the following error message:
?clock not set
You must reset the date and time each time you turn on the PK-232. Otherwise CON-
STAMP and MSTAMP won't "stamp" the time. If you type DAYTIME without a parameter,
the PK-232 displays current date and time information. The format of the display is
dd-mm-yy hh:mm:ss.
DAYTIME 08-Jul-86 06:57:33
The format for entering the date and time is "yymmddhhmm", where:
yy is the last two digits of the year (00-99)
mm is the two-digit month code (01-12)
dd is the date (01-31)
hh is the hour (00-23)
mm is the minutes after the hour (00-59)
cmd:
daytime 8607080657
4.6.13
Packet Formatting
The PK-232 uses some special characters to control its operations. Many of these special
characters can be used to "edit" commands and text as you type. You can "personalize"
these features to suit you and your computer. Most of the special input characters are ac-
tive in both Command and Converse modes; any exceptions will be noted.
Some of your PK-232's command parameters affect how your packets are formatted –
how your typing appears to the rest of the world. Other commands let you correct typing
errors before your packet is sent, cancel lines, cancel entire packets if necessary.
If the default command character is unsuitable for your computer's terminal program, you
can redefine each function using any ASCII character appropriate to your needs.
See the "Command Summary" chapter for full details on how to define these formatting
and control features and commands.
Содержание PAKRATT PK-232
Страница 1: ...ADVANCED ELECTRONIC APPLICATIONS INC PAKRATT MODEL PK 232 Multi Mode Data Controller Operating Manual ...
Страница 193: ...USER S GUIDE SCHEMATIC DIAGRAMS PK232UG Rev E 9 87 H 1 193 ...
Страница 194: ...USER S GUIDE SCHEMATIC DIAGRAMS PK232UG Rev E 9 87 H 2 194 ...
Страница 195: ...USER S GUIDE PARTS PICTORIAL PK232UG Rev B 9 86 I 1 195 APPENDIX I PARTS PICTORIAL ...