USER'S GUIDE
COMMAND SUMMARY
PK232UG Rev. B 9/86
6-47
149
3
Connect request (SABM or "C") frames and disconnect (DISC or "D") frames are also dis-
played with the headers.
4
Unnumbered acknowledgment (UA) of connect- and disconnect-state frames are also dis-
played with either the characters "UA" or "DM" and a header.
5
Receive Ready (RR), Receive Not Ready (RNR), Reject (RJ), Frame Reject (FRMR) and
(I)-Frames are also displayed.
6
Poll/Final bit, PID and sequence numbers are also displayed.
MDIGI
ON|OFF
Mnemonic:
MD
Default: OFF
Mode: Packet
Parameters:
ON -
I and UI frames having your call sign (MYCALL or MYALIAS) as the next digi-
peater in the field are displayed, whether you are connected or discon-
nected.
OFF - Normal monitoring as determined by the monitoring mode commands.
MDIGI
permits you to display packet frames that your monitor would normally not show when an-
other station uses your station as a digipeater. MDIGI helps you to better understand the digipeat-
ing paths that may involve your station, even when you've been unaware of what's happening on
the channel.
Use
MDIGI
to see why your transmitter is being keyed when you're not actively involved in a com-
munication session or when your system is more active than you would expect.
When
MDIGI
is OFF you'll see those frames that include your station as one of the digipeaters, if
your monitor modes have been set this way. If your monitor modes have not been set so you can
see these frames, set MDIGI ON to display them.
MFILTER
n
1[,
n
2[,
n
3[,
n
4]]]
Mnemonic:
MFI
Default: $07,$13
Mode: Packet
Parameters:
n
-
0 to $80 (0 to 128 decimal) specifies an ASCII character code. Up to four
characters may be specified separated by commas.
Use
MFILTER
to select characters to be "filtered," or excluded from monitored packets. Parameters
"
n
1,", "
n
2", etc., are the ASCII codes for the characters you want to filter. You can enter up to four
characters in either hex or decimal.
To prevent a <CTRL-L> character from clearing your screen, set
MFILTER
12.
To eliminate <CTRL-Z> characters, which some computers interpret as end-of-file markers, set
MFILTER
26.
To eliminate <CTRL-G> characters, which beep your computer or terminal, set
MFILTER
7.
MFROM
ALL/NONE, YES/NO call1[,call2..] Mnemonic
MF
Default: ALL
Mode: Packet
Parameters:
call -
ALL/NONE, YES list/NO list
(list of up to eight call signs, separated by commas).
Содержание PAKRATT PK-232
Страница 1: ...ADVANCED ELECTRONIC APPLICATIONS INC PAKRATT MODEL PK 232 Multi Mode Data Controller Operating Manual ...
Страница 193: ...USER S GUIDE SCHEMATIC DIAGRAMS PK232UG Rev E 9 87 H 1 193 ...
Страница 194: ...USER S GUIDE SCHEMATIC DIAGRAMS PK232UG Rev E 9 87 H 2 194 ...
Страница 195: ...USER S GUIDE PARTS PICTORIAL PK232UG Rev B 9 86 I 1 195 APPENDIX I PARTS PICTORIAL ...