![AEA PAKRATT PK-232 Скачать руководство пользователя страница 132](http://html.mh-extra.com/html/aea/pakratt-pk-232/pakratt-pk-232_operating-manual_2859464132.webp)
USER'S GUIDE
COMMAND SUMMARY
PK232UG Rev. B 9/86
6-30
132
CONNECT
call1 (VIA call2(,call3 .... call9) Mnemonic: C Immediate Command
Mode: Packet
Parameters:
call1 - Call sign of the distant station to which you wish to be connected.
call2 - Optional call sign(s) of up to eight digipeaters via which you'll be repeated to
call9 reach the distant station.
CONNECT
sends a connect request to station "call1", directly or via one or more digipeaters. Each
call sign can include an optional SSID
-n
immediately after the call sign.
The part of the command line shown in brackets below is optional. The double-bracketed text
",call3...,call9" is also optional and is used only when "VIA call2" is used, that is, when connecting
through one or more digipeaters. (The breaks and quotation marks are used in this text only for
clarity – please don't type them!)
VIA call2[, call3 .... ,call9]
Type the digipeater fields in the exact sequence you wish to use to route your packets to desti-
nation station "call1".
If you type
CONNECT
while your PK-232 is connected, or trying to connect to or disconnect from a
distant station, your monitor will show:
Link state is: CONNECT in progress
If the distant station doesn't "ack" your connect request after the number of tries in
RETRY
, the
CONNECT
command is canceled. Your monitor displays:
cmd:*** Retry count exceeded
DISCONNECTED: (call sign)
To connect directly to WX1AAA, you would type:
CONNECT WX1AAA
(or
C WX1AAA
)
To connect to WX1AAA using WX2BBB (with whom you can easily connect) and WX3CCC (who is
near AAA) as digipeaters, you would type:
CONNECT WX1AAA VIA WX2BBB,WX3CCC
Type
CONNECT
or
C
without arguments to see the link status and the number of unacknowledged,
outstanding packets.
CONPERM
ON|OFF
Mnemonic:
CONP
Default: OFF
Mode: Packet
Parameters:
ON -
The current connection on the current channel is not allowed to enter the
disconnected state.
OFF - The current channel can be connected and disconnected from the other sta-
tions.
When ON,
CONPERM
forces the PK-232 to maintain the current connection, even when frames to
the other station exceed
RETRY
attempts for an acknowledgment.
RESTART
and power off/on cy-
cling do not affect this connected state.
Содержание PAKRATT PK-232
Страница 1: ...ADVANCED ELECTRONIC APPLICATIONS INC PAKRATT MODEL PK 232 Multi Mode Data Controller Operating Manual ...
Страница 193: ...USER S GUIDE SCHEMATIC DIAGRAMS PK232UG Rev E 9 87 H 1 193 ...
Страница 194: ...USER S GUIDE SCHEMATIC DIAGRAMS PK232UG Rev E 9 87 H 2 194 ...
Страница 195: ...USER S GUIDE PARTS PICTORIAL PK232UG Rev B 9 86 I 1 195 APPENDIX I PARTS PICTORIAL ...