USER'S GUIDE
COMMAND SUMMARY
PK232UG Rev. B 9/86
6-55
157
NOMODE
ON|OFF
Mnemonic:
NO
Default: OFF
Mode: Packet
Parameters:
ON -
The PK-232 switches modes (Command, Converse, Transparent) only upon
explicit command. NEWMODE function is ignored.
OFF - The PK-232 changes modes according to NEWMODE.
When
NOMODE
is ON your PK-232 never switches from Converse or Transparent Mode to Com-
mand Mode (or vice versa) by itself. Only specific commands (CONVERSE, TRANS, or <CTRL-C>)
typed by you change the operating mode.
When
NOMODE
is OFF, your PK-232 switches modes automatically according to the way
NEW-
MODE
is set.
NUCR
ON|OFF
Mnemonic:
NU
Default: OFF
Mode: All
Parameters:
ON -
<NULL> characters are sent to the terminal following <CR> characters.
OFF - <NULL> characters are not sent to the terminal following <CR> characters.
Some of the older electromechanical terminals (Teletype™ machines) and printer-terminals require
some extra time for the printing head to do a line feed and return to the left margin. NUCR ON sol-
ves this problem by making your PK-232 send <NULL> characters (ASCII code $00) to your com-
puter or terminal. This introduces any necessary delay after any <CR> sent to the terminal.
The
NULLS
command sets the number of individual <NULL> characters that are to be sent when
NUCR is ON.
Set
NUCR
ON if your terminal or printer misses one or more characters after responding to a
<CR>. if this is the case, you will sometimes see overtyped lines.
NULF
ON|OFF
Mnemonic:
NUL
Default: OFF
Mode: All
Parameters:
ON -
<NULL> characters are sent to the terminal following <LF> characters.
OFF - <NULL> characters are not sent to the terminal following <LF>s.
Some of the older electromechanical terminals (Teletype™ machines) and printer-terminals require
some extra time for the printing head to do a line feed and return to the left margin.
NULF
ON sol-
ves this problem by making your PK-232 send <NULL> characters (ASCII code $00) to your com-
puter or terminal. This introduces any necessary delay after any <LF> sent to the terminal.
The
NULLS
command sets the number of individual <NULL> characters that are to be sent when
NULF
is ON.
Set
NULF
ON if your terminal or printer misses one or more characters at the beginning of a
new line after responding to a <LF>.
Содержание PAKRATT PK-232
Страница 1: ...ADVANCED ELECTRONIC APPLICATIONS INC PAKRATT MODEL PK 232 Multi Mode Data Controller Operating Manual ...
Страница 193: ...USER S GUIDE SCHEMATIC DIAGRAMS PK232UG Rev E 9 87 H 1 193 ...
Страница 194: ...USER S GUIDE SCHEMATIC DIAGRAMS PK232UG Rev E 9 87 H 2 194 ...
Страница 195: ...USER S GUIDE PARTS PICTORIAL PK232UG Rev B 9 86 I 1 195 APPENDIX I PARTS PICTORIAL ...