4.6.12.3
The
MCON
Command
Use the
MCON
command for selective monitoring of other traffic on the channel while
connected to a distant station. Use this feature to have your PK-232 "listen" for a specif-
ic station while you are connected to and conversing with someone else.
Set
MCON
to
0
(zero) or
OFF
to monitor packet activity when your station is not con-
nected, but have all monitoring automatically cease when you are connected to some-
one.
MCON
works like
MONITOR
but affects your display while connected. As
MCON
settings
are increased, more functions are added in monitoring sequences. The meaning of the
parameters values are identical to those shown under the
MONITOR
command.
4.6.12.4
The
MFILTER
Command
Use the
MFILTER
command to "filter" selected characters from packets received. For ex-
ample, you can command your PK-232 system to filter out form feeds, bell characters
or extra <LF> that may be sent by the station with which you're connected, but which
may interfere with your display or otherwise disturb your operations. You can specify up
to four characters by giving the ASCII character code in hex or decimal. Some examples
follow:
o To prevent a <CTRL-L> character from clearing your screen, set
MFILTER
to
12
.
o To eliminate <CTRL-Z> characters, which some computer interpret as end-of-file
markers, set
MFILTER
to
26
.
o To prevent <CTRL-G> characters from "beeping" your computer or terminal, set
MFILTER
to
7
.
Enter the ASCII or hexadecimal values of the selected characters separating each value
with a comma:
cmd:
MFILTER $07,$13
4.6.12.5
The
MHEARD
Monitor Buffer
Use the
MHEARD
command to display a list of stations heard since the last time your
PK-232 was powered up, or since the last time the
MHEARD
buffer was cleared.
Clear the MHEARD buffer by typing either a "percent sign" (
%
), an ampersand (
&
),
N
,
NO
,
NONE
or
OFF
after the command word.
o Stations that are heard directly are marked with a
*
.
o Stations heard through a digipeater are not marked.
Entries in the "heard" report are also time stamped if the date and time has been set.
The PK-232's time is updated continuously as long as it is powered.
4.6.12.6
MSTAMP
– The Monitor Time-Stamp Command
Monitored packets can be time-stamped if
DAYTIME
has been set. to enable this func-
tion, set
MSTAMP ON
. You can also time-stamp connect and disconnect messages with
to command
CONSTAMP ON
.
Содержание PAKRATT PK-232
Страница 1: ...ADVANCED ELECTRONIC APPLICATIONS INC PAKRATT MODEL PK 232 Multi Mode Data Controller Operating Manual ...
Страница 193: ...USER S GUIDE SCHEMATIC DIAGRAMS PK232UG Rev E 9 87 H 1 193 ...
Страница 194: ...USER S GUIDE SCHEMATIC DIAGRAMS PK232UG Rev E 9 87 H 2 194 ...
Страница 195: ...USER S GUIDE PARTS PICTORIAL PK232UG Rev B 9 86 I 1 195 APPENDIX I PARTS PICTORIAL ...