USER'S GUIDE
COMMAND SUMMARY
PK232UG Rev. B 9/86
6-62
164
The PK-232 enters the disconnected state if the number of retries is exceeded.
If you are not in Transparent Mode, the following message is displayed:
*** Retry count exceeded
*** DISCONNECTED: {call sign}
RXREV
ON|OFF
Mnemonic:
RXR
Default: OFF
Mode: Baudot and ASCII RTTY/AMTOR
Parameters:
ON -
Received data polarity is reversed (mark-space reversal).
OFF - Received data polarity is normal.
Use the
RXREV
Command to invert the polarity of the data demodulated from the received mark
and space tones.
In some cases, you may be trying to copy a station that's transmitting "upside down" but receiving
your signals correctly.
Set
RXREV
ON to reverse the data sense of received signals.
Type
RXREV TOG
(
RXR T
) to "toggle" the polarity of received signals. This is useful when trying
various combinations of
RBAUD
and
RXREV
to decode an unknown Baudot signal.
SELFEC
aaaa
Mnemonic:
SEL
Default: empty
Mode: AMTOR FEC
Parameters:
aaaa
- Specifies your SELective CALling code (SELCALL).
The
SELFEC
command starts a SELective FEC (Mode Bs) transmission to a specific distant station
when you enter that station's SELCALL (SELective CALLing) code.
The
SELFEC
command must be a unique character sequence that contains four alphabetic charac-
ters. It is normally derived from the call sign of the distant station.
See
MYSELCAL
for further information on the derivation and use of SELCALs.
To end your SELFEC transmission, return to the Command Mode by typing
<CTRL-C>
(default
value) and then typing
R
to switch back to receive mode.
You don't have to type the SELCAL a second time if you intend to call the same station again right
away.
SENDPAC
n
Mnemonic:
SE
Default: $0D <CTRL-M>
Mode: Packet
Parameters:
n
-
0 to $7F (0 to 127 decimal) specifies an ASCII character code.
Use the
SENDPAC
command to select the character used to force a packet to be sent in Converse
Mode. The parameter
n
is the numeric ASCII code for the character you want to use to force your
input to be packetized and queued for transmission. You can enter the code in either hexadecimal
or decimal numbers.
Содержание PAKRATT PK-232
Страница 1: ...ADVANCED ELECTRONIC APPLICATIONS INC PAKRATT MODEL PK 232 Multi Mode Data Controller Operating Manual ...
Страница 193: ...USER S GUIDE SCHEMATIC DIAGRAMS PK232UG Rev E 9 87 H 1 193 ...
Страница 194: ...USER S GUIDE SCHEMATIC DIAGRAMS PK232UG Rev E 9 87 H 2 194 ...
Страница 195: ...USER S GUIDE PARTS PICTORIAL PK232UG Rev B 9 86 I 1 195 APPENDIX I PARTS PICTORIAL ...