![AEA PAKRATT PK-232 Скачать руководство пользователя страница 105](http://html.mh-extra.com/html/aea/pakratt-pk-232/pakratt-pk-232_operating-manual_2859464105.webp)
USER'S GUIDE
COMMAND SUMMARY
PK232UG Rev. B 9/86
6-3
105
6.2.
Command List
Commands are listed alphabetically in the following command descriptions. Each command
entry contains several sections:
o
Command name
o
Command abbreviation or mnemonic
o
Default value
o
Parameters
6.2.1.
Command Names
The command name at the beginning of the description is the full word you can type in
order to have your PK-232 execute this command. Next to the command you'll see the
minimum abbreviation or the mnemonic that you can use instead of the full word. Of
course, you can always type out the entire command word, or any abbreviation longer
than the minimum abbreviation. For example:
o
You can enter the command
MYCALL
by simply typing
MY
.
The abbreviation "M" is not sufficient (and will be interpreted as a different command),
but
MY
,
MYC
,
MYCA
,
MYCAL
or
MYCALL
are all acceptable.
If a command requires parameters, the type of parameter is indicated after the command
name as well as the default value. For example:
o
n
means the command takes a numerical parameter value.
6.2.2.
Default Values
Some commands have initial values that your PK-232 assumes as defaults or "used most
often". These defaults are stored in EPROM and loaded into RAM when the PK-232 is first
turned on – or when you type the
RESET
command.
6.3.
Parameters, Arguments and Values
Some commands need additional information before they can be executed. This type of
command has "parameters" or requires "arguments". For example, a command such as
FULLDUP
has a Boolean parameter. When you type
FULLDUP ON
,
FULLDUP
is the command,
ON
is its argument – the value you want the PK-232 to use to execute the command
FULL-
DUP
.
o
The values that fill this parameter are either ON or OFF.
o
Immediate commands such as 'ID' have no parameters. Typing only
ID
causes the
PK-232 to execute the command.
Some commands such as
CONNECT
have optional parameters.
o
If you type
CONNECT
without an argument, the PK-232 displays the current status
of the link.
However, if you type
CONNECT N7ML
, the PK-232 issues the connect request and tries to
establish the link to N7ML.
Содержание PAKRATT PK-232
Страница 1: ...ADVANCED ELECTRONIC APPLICATIONS INC PAKRATT MODEL PK 232 Multi Mode Data Controller Operating Manual ...
Страница 193: ...USER S GUIDE SCHEMATIC DIAGRAMS PK232UG Rev E 9 87 H 1 193 ...
Страница 194: ...USER S GUIDE SCHEMATIC DIAGRAMS PK232UG Rev E 9 87 H 2 194 ...
Страница 195: ...USER S GUIDE PARTS PICTORIAL PK232UG Rev B 9 86 I 1 195 APPENDIX I PARTS PICTORIAL ...