5.
Install grease drain tubing to ensure waste oil flows into the sump tank.
6.
Remove the grease injection port M10x1 plug, install the grease injection
nozzle, and use manual grease injection gun to inject grease until the new
grease is discharged from the outlet.
7.
Release the grease pressure inside the reducer as shown in Table 13-3.
8.
The amount of oil discharged by weighing shall be equal to the amount of
oil injected. If the discharge amount is less than the injection amount, the
excess amount is discharged by gas at the fat injection port. If the
discharge volume is greater than the injection volume; From the fat outlet
injection lack of quantity can be.
9.
Remove the grease injector, install the M10x1 plug on the grease outlet
and grease injector, and apply the sealing tape/sealant.
Caution
◼
When injecting fat from the fat injection port into the inner part of the
operation machine, the fat injection speed by hand pump is less than 8g/s
and the fat injection pressure is less than 0.3mpa.In order to ensure the
smooth elimination of the old oil inside the reducer, fter a period of oil
injection, take a rest for a while, such as the oil outlet no old oil discharge
to continue the oil injection. When the oil filling speed is too fast, the
instantaneous pressure inside the reducer becomes higher, and the
grease may cause damage to the motor oil seal and the grease enters the
motor.
J3 axis reducer replacement grease process
Figure 13-7
Replace J3 shaft reducer grease
Grease
Injection
Grease Outlet