AIR50-2230A Operation Manual
Installation of AIR50-2230A manipulator
17
◼
Strength of chemical bolt is subject to the strength of concrete. Therefore,
the safety shall be fully considered according to the design guidelines of
manufacturer before the construction.
The names and specifications of parts required to fix the manipulator are as
shown in
Table 6-1 Parts for Fixing AIR50-2230A Manipulator
Part Name
Remarks
Ground fixing
Bracket
fixing
Fixing screw
Four M20x40 (Grade 12.9) 4
pieces
○
○
Chemical bolt
Four M20 (not less than Grade
4.8) 8 pieces
○
○
Fixing plate of
robot
25 mm, 1 piece
○
Mounting bracket
25 mm, 4 piece
○
Prompt
◼
There shall be no insulating materials between the fixing plate and
mounting bracket of robot and the manipulator and concrete.
◼
Mark "
○
" means that the part is in need
◼
Bracket shall be firmly installed on the ground with the strength not less
than the fixing strength between the fixing plate of robot and the ground
for the ground fixing (mode 1).
Ground fixing
Ground fixing process (mode 1) is as follows:
1.
Hold the fixing plate of robot close to the mounting surface and secure it
with 8 piece M20 chemical bolts (strength not less than Grade 4.8).
2.
Install the manipulator base on the fixing plate with four M20X40 bolts
(Grade 12.9).