__________________________________________________________________________________________
PAC-4010 User Manual V1.0 Copyright 2016 Advantech Co. Ltd. All rights reserved. Page
50
3.4.5 PuTTY Configuration
Assuming PuTTY have been installed successfully on the terminal PC with Microsoft
Windows, the user can check the COM port (UART) number under
“COM and LPT”
in
the
“Device Manager”
, which can be accessed by entering the
“Control Panel”
followed by opening up
“System”
and then
“Hardware”
. Let us assume the CP210x
USB to UART Bridge Controller has been assigned with
“COM3”
. User can open up
PuTTY and begin the configuration as shown below. If you use the RJ45 (COM2) and a
serial port on the terminal PC, please use the COM port number of that serial port
instead of
“COM3”
.
- Specify COM3 under serial line and 115200 for speed, no parity, no flow control.
- Check Serial for connection type.
- Click the
“
Open
”
button and a PuTTY terminal screen will appear.
Figure 3-17: PuTTY Configuration (A)