67
Futuresun HP V2
CAUTION!
The UV-lamp in the
SunFresh container
could be damaged during
replacement. Never touch
the UV-lamp. Replacement
of UV lamp must be
performed by authorized
service personnel.
The water level is controlled by a sensor. If the
minimum level of the SunFresh container is reached,
the display shows the message “E 06”. In this case,
the SunFresh container needs to be refilled. Proceed
as follows:
Deactivate the mains disconnection switch and
secure with lock and key against accidental
activation.
Lift up the sunbed acrylic (1).
Pull up the support bar (2) and when in straight
position, push the support down until it snaps in
(3).
Let the sunbed acrylic down so that it is supported
by the support bar.
Remove the front cover plate as described in the
chapter "Removal of front cover plate".
Take the SunFresh off the assembly plate for
the SunFresh container and condensation water
container.
Take out the germicidal unit.
Survey germicidal unit:
1
Hose (blue)
2
Supply cable
3
UV-lamp
4
SunFresh-container
5
Plunge pipe
CAUTION!
Use only distilled water for
refill. The SunFresh function
may be affected by using
non-dimineralized water
If necessary refill with distilled water to the max.
mark.
Put the plunge pipe into the lid of the germicidal
unit.