35
Futuresun HP V2
1
Terminals for control and sensor connections
2
Mains supply connection
3
Strain relief for mains supply connection
DANGER
RISK OF ELECTRIC
SHOCK!
Only a certified electrician
according to EN 60204-
1/VDE 0113 and current
EVU-standards is allowed
to perform the electrical
connection.
For export units: All local/
national standards and
regulations apply!
Connect the mains supply.
Fasten the strain relief.
Connect the time control device as described in the
attachment "Assignment of terminals".
Connect the ballast tray inserts to the terminals.
Connect the remaining terminals from the top
canopy and the sunbed to the ballast tray inserts
on the ballast tray. See also "Assignment of
terminals".
Connect the connection cable of the control panel
to the main PCB( display connection).
Insertion of ballast tray
DANGER
RISK OF ELECTRIC
SHOCK!
When pulling out or pushing
in the ballast tray, cables
can get pinched and
damaged. Always move
ballast tray carefully. Make
sure that no cables get
pinched between ballast
tray and sunbed.
After assembly of the ballast tray inserts, the ballast
tray can be put onto the guide rails of the sunbed.
Proceed as follows.