Motus Reference Manual
Page 26 of 146
Version 1.1
29/11/2019
9.4
Rugged Communication Specifications
Parameter
Value
Interface
RS232 (RS422 optional)
Primary and Auxiliary Port Speed
2400 to 2 M baud
GPIO Port Speed
2400 to 250 K baud
Protocol
AN Packet Protocol
NMEA
TSS1
Simrad
Peripheral Interface
2x GPIO and 1x Auxiliary RS232
GPIO Level
5 V or RS232
Table 10: Rugged communication specifications
9.5
OEM Communication Specifications
Parameter
Value
Interface
3.3V TTL serial port (5V tolerant input)
Speed
2400 to 10M baud
Protocol
AN Packet Protocol
Peripheral Interface
2x GPIO and 1x Auxiliary serial port (3.3V
TTL)
GPIO Level
3.3V TTL (5V tolerant input)
Table 11: OEM communication specifications
9.6
Rugged Hardware Specifications
Parameter
Value
Operating Voltage
5 to 36 V
Input Protection
±
-60 V
Power Consumption
0.95 W (typical)
Hot Start Battery Capacity
> 48 hrs
Hot Start Battery Charge Time
30 mins
Hot Start Battery Endurance
> 10 years
Operating Temperature
-40 °C to 85 °C
Environmental Sealing
IP67
MIL-STD-810G
Shock Limit
2000 g
Vibration Limit
8 g
Содержание Motus
Страница 1: ...Motus Reference Manual ...
Страница 21: ...Motus Reference Manual Page 20 of 146 Version 1 1 29 11 2019 same folder as the Motus Manager software ...
Страница 38: ...Motus Reference Manual Page 37 of 146 Version 1 1 29 11 2019 ...
Страница 79: ...Motus Reference Manual Page 78 of 146 Version 1 1 29 11 2019 Illustration 58 Motus OEM connector pin numbering ...
Страница 90: ...Motus Reference Manual Page 89 of 146 Version 1 0 29 11 2019 ...
Страница 91: ...Motus Reference Manual Page 90 of 146 Version 1 0 29 11 2019 ...