3-4
Specifications
5706058-A
Advanced Energy
®
Pressure
5.17 bars (75 psi) maximum inlet water pressure
Contaminates
•
The following specifications are recommended for the wa-
ter used to cool the RFG 3001 generator:
•
pH between 7 and 9
•
Total chlorine < 20 ppm
•
Total nitrate < 10 ppm
•
Total sulfate < 100 ppm
•
Total dissolved solids < 250 ppm
•
Total hardness expressed as calcium carbonate equivalent
less than 250 ppm
•
Specific resistivity of 2500
Ω
/cm or higher at 25
°
C
•
Total dissolved solids (TDS) as estimated by the follow-
ing:
TDS
≤
640,000
specific resistivity (
Ω
/cm)
Table 3-4. Environmental Specifications
WARNING:
Do not use de-ionized water for cooling purposes. De-ionized water causes both
corrosion and erosion of cooling manifolds.