Troubleshooting and Customer Support
5706058-A
Advanced Energy
®
Troubleshooting Tables
Table 7-1. No Power
AC
ON
LED
RF
ON
LED
Intlk
Open
LED
Over
temp
LED
Power
Limit
LED
Probable Cause
Action
On
Off
On
Off
Off
The interlock string
is open. The RF out-
put cable is not con-
nected or loose. Pins
10 and 23 on the
User port are not
connected.
Install and/or tighten the
RF output connector. Con-
nect pins 10 and 23 on the
User port. After the condi-
tion is resolved, toggle the
RF On command off and
then back on again.
Off
Off
Off
Off
Off
The circuit breaker
is off. The generator
had no cooling
water for a long
period of time
resulting in AUX
supply shut down.
Turn the circuit breaker
on. Check the cooling
water for proper opera-
tion. Let the generator cool
down. The AUX supply
will automatically turn
back on when cool.
On
On
Off
On
Off
An overtemperature
condition has been
detected in the gen-
erator. Cooling
water is probably
out of specifications.
Check cooling water and
ensure it is within specifi-
cations. After overtemper-
ature condion is resolved,
toggle RF On command
off and then on again.
Table 7-2. The Power Level Doesn’t Meet Setpoint
AC
ON
LED
RF
ON
LED
Intlk
Open
LED
Over
temp
LED
Power
Limit
LED
Cause
Action
On
On
Off
Off
On
The generator is
unable to supply the
requested power
level due to limiting
conditions in the
generator. Power
limits can be caused
by load mismatches.
Adjust the load or reduce
the power level.
Содержание RFG 1251
Страница 2: ......
Страница 3: ...User Manual RFG 1251 Generator 5706058 A...
Страница 8: ...x List of Figures 5706058 A Advanced Energy...
Страница 10: ...xii List of Tables 5706058 A Advanced Energy...
Страница 16: ...1 6 Introduction 5706058 A Advanced Energy...
Страница 33: ...5706058 A Connectors Indicators and Controls 4 9 RFG 1251 Generator CONNECTOR PANEL Figure 4 5 RFG 1251 panel...
Страница 34: ...4 10 Connectors Indicators and Controls 5706058 A Advanced Energy...
Страница 36: ...5 2 Installation 5706058 A Advanced Energy DIMENSIONAL INFORMATION Figure 5 1 RFG 1251 dimensions NEED...
Страница 38: ...5 4 Installation 5706058 A Advanced Energy...
Страница 46: ...7 6 Troubleshooting and Customer Support 5706058 A Advanced Energy...