5706058-A
Introduction
1-5
RFG 1251 Generator
This device must be installed and used only in compliance with the standards listed in addition
to VDE 0113, EN 60204 (IEC 204), and applicable requirements.
For more information, refer to the letter of conformance (US) or declaration of conformity
(EU) accompanying the product.
Installation Requirements
Conditions of Use
To be in compliance with the stated directives and standards, you must meet the following
conditions of use.
•
This device must be used in an overvoltage category II installation only. Install and
operate this device with an approved isolation transformer on the ac input.
•
Before making any other connection, connect the auxiliary Protective Earth ground
conductor on the rear panel.
•
Use only a shielded cable on the input power connector.
•
Use only a shielded power cable on the output power connector.
•
Install and operate this device only in a pollution degree 2 or better environment, which
means an indoor location such as a computer room, office, or factory floor where only
non-conductive pollution occurs during operation. Occasionally, a temporary conductivity
caused by condensation occurs when the device is not operating.
•
Non-standard connectors for input and/or output power must be inaccessible to the user.
•
To provide the required over-current protection, install and operate this device with an
AE-approved circuit breaker on the ac input.
WARNING:
Operating and maintenance personnel must receive proper training before installing,
troubleshooting, or maintaining high-energy electrical equipment. Potentially lethal
voltages could cause death, serious personal injury, or damage to the equipment.
Ensure that all appropriate safety precautions are taken.
Содержание RFG 1251
Страница 2: ......
Страница 3: ...User Manual RFG 1251 Generator 5706058 A...
Страница 8: ...x List of Figures 5706058 A Advanced Energy...
Страница 10: ...xii List of Tables 5706058 A Advanced Energy...
Страница 16: ...1 6 Introduction 5706058 A Advanced Energy...
Страница 33: ...5706058 A Connectors Indicators and Controls 4 9 RFG 1251 Generator CONNECTOR PANEL Figure 4 5 RFG 1251 panel...
Страница 34: ...4 10 Connectors Indicators and Controls 5706058 A Advanced Energy...
Страница 36: ...5 2 Installation 5706058 A Advanced Energy DIMENSIONAL INFORMATION Figure 5 1 RFG 1251 dimensions NEED...
Страница 38: ...5 4 Installation 5706058 A Advanced Energy...
Страница 46: ...7 6 Troubleshooting and Customer Support 5706058 A Advanced Energy...