5706058-A
Connectors, Indicators, and Controls
4-3
RFG 1251 Generator
Table 4-2. User Port Pins
Signal
Pin
Return
Pin
Signal Name
Signal
Type
Signal Description
14
1
SETPOINT
STATUS
Digital
Output
A low-impedance path between these
pins indicates that an internal power
limit has been encountered. When RF
power is enabled, a high impedance
path between these pins indicates that
the generator is “at setpoint”.
2
15
REFL PWR
MONITOR
Analog
Output
This 0 to 10 V signal represents the
reflected power as measured at the
output of the generator. This signal is
scaled to represent 0 to 1250 W.
3
16
FWD/DELV PWR
MONITOR
Analog
Output
This 0 to 10V signal represents the
forward or delivered power as
measured at the output of the generator.
See pin 8 for power regulation mode
selection. This signal is scaled to
represent 0 to 1250 W.
4
17
RF PWR ON
Digital
Input
This signal is used to control the RF
output of the generator. A voltage level
of 4 to 30 V on pin 4 enables the RF
power. If pin 4 is open or grounded, RF
power is disabled. Note that the return
pin (pin 17) is common to both this
signal and to the PWR REG MODE
signal (see pin 8).
5
18
SETPOINT
Analog
Input
This 0 to 10 V signal defines the
desired setpoint for the generator's RF
output. It is scaled to represent 0 to
1250 W.
6
19,21
+24V DC
Reference
Voltage
This dc voltage may be used for
controlling the RF power through pin 4
(pin 6 may be tied to pin 4 to enable the
RF power). The maximum current
capacity for this signal is 50 mA.
20
7
RF STATUS
Digital
Output
A low impedance path between these
pins indicates that the RF power is
present at the output of the generator.
The interlock loop must be closed and
the RF PWR ON signal must be active
to enable RF power.
Содержание RFG 1251
Страница 2: ......
Страница 3: ...User Manual RFG 1251 Generator 5706058 A...
Страница 8: ...x List of Figures 5706058 A Advanced Energy...
Страница 10: ...xii List of Tables 5706058 A Advanced Energy...
Страница 16: ...1 6 Introduction 5706058 A Advanced Energy...
Страница 33: ...5706058 A Connectors Indicators and Controls 4 9 RFG 1251 Generator CONNECTOR PANEL Figure 4 5 RFG 1251 panel...
Страница 34: ...4 10 Connectors Indicators and Controls 5706058 A Advanced Energy...
Страница 36: ...5 2 Installation 5706058 A Advanced Energy DIMENSIONAL INFORMATION Figure 5 1 RFG 1251 dimensions NEED...
Страница 38: ...5 4 Installation 5706058 A Advanced Energy...
Страница 46: ...7 6 Troubleshooting and Customer Support 5706058 A Advanced Energy...