ENGLISH
SERVICE MANUAL
102
33019746(2)2010-03
RS 501
IMPIANTO IDRAULICO
TROUBLESHOOTING
See the previous chapters related to the use of the hydraulic system.
HYDRAULIC SYSTEM OIL LEVEL AND DRAIN FILTER EFFICIENCY CHECK
CAUTION!
This procedure must be performed with the hopper (3) fully retracted.
Engage the parking brake with the lever (66).
1.
Start the diesel engine and run it at 1.500 rpm, according to the procedure shown in the Instructions for use Manual.
2.
Open the right door (20) by releasing the fasteners (21) with the supplied key.
3.
Check that the needle of the effi ciency indicator (D) of the drain fi lter (C) is in the green area (E), otherwise the fi lter (C) must
4.
be replaced (see the procedure in the relevant paragraph).
Check that there are no oil leaks in the upper area (F) of the hydraulic system oil tank.
5.
Turn the ignition key (76) to OFF position and remove it.
6.
Using the indicator (A), check that the oil level in the tank is between the MIN and MAX marks.
7.
CAUTION!
If the hydraulic oil level is low, the warning light (84) turns on and the machine stops after 20 seconds.
If necessary, unscrew the plug (G) and top up. For the types of oil to be used, see the Technical Data chapter.
8.
NOTE
Top up by using the same type of oil that is in the tank.
Screw down the plug (G).
9.
Close the right door (20) by engaging the fasteners (21) with the supplied key.
10.
S301620
Содержание ADVANCE RS 501
Страница 2: ...RS 501 Nilfisk 502 SERVICE MANUAL ENGLISH 33019746 2 2010 03...
Страница 3: ......
Страница 57: ...ENGLISH SERVICE MANUAL 54 33019746 2 2010 03 RS 501 STERZO...
Страница 146: ......
Страница 147: ......
Страница 148: ......
Страница 149: ......
Страница 150: ......
Страница 151: ......
Страница 152: ......
Страница 153: ......
Страница 154: ......