SERVICE MANUAL
ENGLISH
RS 501
33019746(2)2010-03
103
IMPIANTO IDRAULICO
HYDRAULIC SYSTEM OIL LEVEL SENSOR REPLACEMENT
CAUTION!
When there is a short in the level sensor, the detection system determines that the oil level is low and stops the
machine after about 20 seconds. When there is an open in the lever sensor, the detection system determines
that the oil level is high.
Drive the machine on a solid and level ground, then engage the parking brake with the lever (66).
1.
Open the right door (20) by releasing the fasteners (21) with the supplied key.
2.
With a suitable ladder, reach the upper side of the hydraulic oil tank (33).
3.
Locate the level sensor (A).
4.
Disconnect the connector (B).
5.
With a Ø27 socket wrench, unscrew the sensor (A) and replace it.
6.
Connect the connector (B) to the sensor.
7.
Close the right door (20) by engaging the fasteners (21) with the supplied key.
8.
A
B
S341046