ELECTRICAL SYSTEM
FORM NO. 56043089 - AquaRide
™
-
59
MAIN CONTROLLER ERROR CODES (CONTINUED)
Error Code
Fault Description
Troubleshooting Action
E08
Solution solenoid overload
1. Check for a wiring problem. 2. Check coil resistance (spec. is
185 Ohms + or – 15%). Replace solution solenoid if lower than 157
Ohms.
E17
Scrub deck lift actuator
1. Check for disconnected actuator wiring, open in
circuit open (**)
wiring or defective actuator motor. Repair or replace. 2. Check controller
output voltage should be 36V if 0V controller failure (replace).
E18
Scrub deck lift actuator short
1. Check for binding or frozen brush lift linkage and excessive weight
on brush deck. 2. Check for short circuit* in brush lift motor and wiring.
Repair or replace.
E21
Scrub motor circuit open (**)
1. Check for open in brush motor wiring or defective motor.
2. Check the negative supply cable at the brush motor for a wiring
problem or improper modi
fi
cations (this is a special cable and must be
replaced with the original OEM).
3. Check resistance on brush motor solenoid. Nominal resistance specs are:
• K1 -
White-Rodgers
brand = 120 Ohms
• K1 -
Ametek
®
brand = 102 Ohms
If the resistance is less than 20% from spec, replace the solenoid.
4. Check if brushes are installed.
E22
Scrub motor short
Same as E06.
E23
Vacuum motor circuit open (**)
1. Check for disconnected vacuum motor wiring, open in wiring and defective
vacuum motor. Repair or replace.
2. Check resistance on vac motor solenoid. Nominal resistance specs are:
• K2 -
White-Rodgers
brand = 120 Ohms
• K2 -
Ametek
®
brand = 98.5 Ohms
If the resistance is less than 20% from spec, replace the solenoid.
3. Check controller output voltage should be 36V if 0V controller failure
(replace).
E24
Vacuum motor short
Same as E07
E25
Solution solenoid circuit open (**) 1. Check for disconnected solenoid wiring plug, open in wiring or
defective solenoid. Repair or replace. 2. Check controller output voltage
should be 36V if 0V controller failure (replace).
E26
Coil / solution solenoid short
1. Check for a short circuit* in wiring or solenoid coil. Repair or replace.
E27
No accessory / wiring
1. Loss of battery (pos.) output to all system contactors (brush, solution
solenoid and vacuum) and system accessories (headlight, warning
beacon, solution pump). 2. Check controller accessory terminal output
(J2-8 Wht/Brn wire) voltage should be 36V if 0V controller failure
(replace).
*Short Circuit de
fi
nition:
• A short circuit is a parallel path of very low resistance, often caused accidentally.
• With low resistance there is an excessive amount of current.
• The excessive current will either melt the wires or open a fusible link.
revised 10/09
Содержание 56314009
Страница 1: ...5 03 revised 10 09 Form Number 56043089 AquaRide SERVICE MANUAL Advance MODEL 56314009...
Страница 7: ...FORM NO 56043089 AquaRide 5 SPECIFICATIONS...
Страница 25: ...WHEEL DRIVE SYSTEM FORM NO 56043089 AquaRide 23 A FRONT D F G E L J K I H N O Q P M R FIGURE 6...
Страница 46: ...44 FORM NO 56043089 AquaRide RECOVERY SYSTEM FIGURE 3...
Страница 49: ...RECOVERY SYSTEM FORM NO 56043089 AquaRide 47 FIGURE 5 FIGURE 6...
Страница 55: ...ELECTRICAL SYSTEM FORM NO 56043089 AquaRide 53 FIGURE 4 FIGURE 3...
Страница 72: ...70 FORM NO 56043089 AquaRide ELECTRICAL SYSTEM Drive Motor Breakdown...
Страница 79: ......