FORM NO. 56043089 - AquaRide
™
-
13
FUNCTIONAL DESCRIPTION OF CONTROL SWITCHES (CONTINUED)
Accessory Vacuum ON/OFF Switch
(I)
- This switch is used when an external scrub wand is used. Pressing this switch will turn the vacuum
on continuously without regard to the throttle position. It will also enable the solution pump. If the scrub system was on it will be turned off. This
includes turning off the scrub brush(s) and raising the scrub deck and turning the solution
fl
ow to the scrub deck off.
NOTE: Automatic shutoff of the
vacuum motor when the recovery bladder is full is disabled when the wand is enabled. The
fl
oat in the recovery bladder will still prevent water from
entering the vacuum motor, but the motor will not shut off.
Key Switch / Main Power
(J)
– Main Power Switch.
Speed Select Switch
(L)
– This switch will allow the operator to select a faster travel speed while the scrub system is enabled thereby allowing
extracting at a higher rate of speed. This option can be disabled if desired. See the Electrical System
“Main Control Board Special Program Options”
for details.
The transport, maintenance mode, and restoration mode speed limits can be programmed using a Curtis handheld programmer. Refer to the
Electrical System
“Main Control Board Special Program Options”
for details.
Horn Switch
(N)
– This switch will sound the horn as long as the switch is held.
The horn also functions as an automatic back-up alarm when the throttle is moved to the reverse position. The volume of the back-up alarm is
programmable. It can also be programmed to provide an annunciation feature that will sound whenever the throttle is in the forward position. See
the Electrical System
“Main Control Board Special Program Options”
for details.
Vacuum Switch
(O)
- This switch is used to turn the vacuum system on or off. Pressing this switch will alternate between on and off. The vacuum
will only turn on when the throttle is moved from the neutral position. It will remain on for 10 seconds after the throttle returns to neutral.
The vacuum also has an automatic shutoff feature that will turn the vacuum and scrub systems off if the recovery bladder becomes full. If this occurs,
the status display will show the word “FULL”. This feature can be disabled if desired. The shutoff threshold can also be adjusted if necessary. See
the Electrical System
“Main Control Board Special Program Options”
for details.
Solution Switch (R)
- This switch is used to turn the solution system on or off. Pressing this switch when the scrub system has been activated will
alternate between on and off. The solution
fl
ow will only turn on when the throttle is moved from the neutral position in the forward direction. The
solution
fl
ow will turn off if the throttle returns to neutral or is moved to reverse.
KNOW YOUR MACHINE
Содержание 56314009
Страница 1: ...5 03 revised 10 09 Form Number 56043089 AquaRide SERVICE MANUAL Advance MODEL 56314009...
Страница 7: ...FORM NO 56043089 AquaRide 5 SPECIFICATIONS...
Страница 25: ...WHEEL DRIVE SYSTEM FORM NO 56043089 AquaRide 23 A FRONT D F G E L J K I H N O Q P M R FIGURE 6...
Страница 46: ...44 FORM NO 56043089 AquaRide RECOVERY SYSTEM FIGURE 3...
Страница 49: ...RECOVERY SYSTEM FORM NO 56043089 AquaRide 47 FIGURE 5 FIGURE 6...
Страница 55: ...ELECTRICAL SYSTEM FORM NO 56043089 AquaRide 53 FIGURE 4 FIGURE 3...
Страница 72: ...70 FORM NO 56043089 AquaRide ELECTRICAL SYSTEM Drive Motor Breakdown...
Страница 79: ......