– 3 –
ADT
STANDARD PROGRAMMING FORM
■
Local programming requires the use of a 2-line Custom English touchpad connected to the touchpad
terminals on the control.
■
Values shown in boxes are “ Standard” ADT defaults.
Field
Function
Programming Selections
––––– –––––––––––––––––––––––––––– –––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––
SYSTEM SETUP (
✱
20-
✱
27)
✱
20 INSTALLER CODE
6
3
2
1
4 digits, 0-9.
✱
21 QUICK ARM ENABLE
†
1
0 = no; 1 = yes.
✱
22
RF SYSTEM TYPE
0
0 = none; 1 = 5800 (5881 Type RF Receiver) with no RF jam detection; 4 = 5800
with RF jam detection.
✱
23 FORCED BYPASS FUNCTION
†
1
0 = none; 1 = bypass open zones.
✱
24 RF HOUSE ID CODE
0
0
Enter 01-31 if a 5827 or 5827BD Touchpad is used in a 5800 RF system.
✱
25 OUTPUT RELAY MODULE
†
0
0 = none; 3 = 4204.
✱
26 VOICE MODULE ACCESS CODE
0
0
1st digit: Enter 1–9; 2nd digit: Enter only #+11 for '
✱
’, #+12 for '#'.
0 in either position = disabled.
✱
27 OUTPUT TO LONG RANGE RADIO
†
0
0 = no; 1 = yes. If yes selected, dialer reports to PRIMARY No. (field
✱
47) will
also be sent via LRR.
ZONE SOUNDS AND TIMING (
✱
28-
✱
39)
✱
28 SINGLE ALARM SOUNDING/ZONE
†
0
0 = no; 1 = yes.
✱
29 FIRE SOUNDER TIMEOUT
†
0
0 = fire sounder timeout; 1 = no fire sounder timeout.
✱
30 ALARM BELL TIMEOUT
†
1
0 = none; 1= 4 min; 2 = 8 min; 3 = 12 min; 4 = 16 min.
✱
36 EXIT DELAY
†
6
0
00–99 seconds.
✱
37 ENTRY DELAY#1
†
4
5
00–99 seconds.
✱
38 ENTRY DELAY#2
†
1
0
00–99 seconds.
✱
39 AUDIBLE EXIT WARNING
†
1
0 = no; 1 = yes.
DIALER PROGRAMMING (
✱
40-
✱
50)
In fields
✱
40,
✱
41,
✱
42, enter up to the number of digits shown. Do not fill unused
spaces. Enter 0-9; #+11 for '
✱
'; #+12 for '#'; #+13 for a pause.
✱
40 PABX ACCESS CODE
E
nter up to 6 digts. If fewer than 6 digits entered, exit by
pressing
✱
(and press 41, if entering next field). To clear entries from field, press
✱
40
✱
.
✱
41 PRIMARY PHONE#
If fewer than 20 digits entered, exit by pressing
✱
(and press 43, if entering next field). To clear entries from field,
press
✱
41
✱
.
✱
42 SECONDARY
PHONE #
If fewer than
20 digits entered, exit by pressing
✱
(and press 43, if entering next field). To clear entries from field,
press
✱
42
✱
.
✱
43 SUBSCRIBER ACCT No.
Enter
0-9; #+11 for B; #+12 for C; #+13 for D; #+14 for E; #+15 for F.
Enter 0 as the first digit of a 4-digit account number for Nos. 0000–0999. End field by pressing
✱
(and press
next field #).
Examples: For Acct No. 1234 , enter:
1
2
3
4
For Acct No. B234, enter:
#+11
2
3
4
✱
45 PHONE SYSTEM SELECT
†
3
If Cent. Sta.
IS NOT on a WATS line: 0 = Pulse Dial;
1 = Tone Dial
If Cent. Sta.
IS on a WATS line:
2 = Pulse Dial ;
3 = Tone Dial
†
Entry of a number other than the one specified will give unpredictable results.
Содержание SA10ADTEG